Table 11. The Configuration Parameters
P000
The Menu Exit
P001
Wire Feed Speed (WFS)
units
P003
Display Options
P004
Recall Memory with
Trigger
P005
Procedure Change
Method
English
Enables exit from menu
Enables change WFS units:
Metric (factory default) = m/min;
English = in/min.
Enables select between one of the four Display Configurations:
"True Energy" = Energy is displayed, along with time in HH:MM:SS format.
"Weld Score" = The accumulative weld score result is shown.
"Big Meters" (factory default) = After 5 seconds of inactivity, only Welding
Current and Voltage is shown on the display, the Welding Parameters Bar
[27] is invisible. To activate the Welding Parameters Bar [27], press the Set
Control [11].
"Standard" = On the Display is shown preset information during and after a
weld.
This option allows a memory to be recalled by quickly pulling and releasing the
gun trigger:
"Enable" = Selecting memories 2 through 9 by quickly pulling and releasing
the gun trigger. To recall a memory with the gun trigger, quickly pull and
release the trigger the number of times that correspond to the memory
number. For example, to recall memory 3, quickly pull and release the
trigger 3 times. Trigger memory recall can only be performed when the
system is not welding.
"Disable" (factory default) = Memory selection is performed only by the
Panel Buttons.
This option selects how remote procedure selection (A/B) will be made. The
following methods can be used to remotely change the selected procedure:
"External Switch" (default) = Dual Procedure selection may only be
performed by the Cross-switch gun or remote control.
"Quick Trigger" = Allows switching between Procedure A and procedure B
while welding with 2-stroke mode. The Cross-switch gun or remote control
is required. To operate:
Select " WFS/Proced. A-B" in P025 to set up parameters for A and B
procedures.
Start the weld by pulling the gun trigger. The system will weld with
procedure A settings.
While welding, quickly release and then pull the gun trigger. The
system will switch to procedure B settings. Repeat to switch back to
procedure A settings. The procedure can be changed as many times
as needed during the weld.
Release the trigger to stop welding. When the next weld is made, the
system will start again with procedure A.
"IntegralTrigProc" = Allows switching between Procedure A and procedure
B while welding with 4-stroke mode. When in 2-step, the system operates
identical to the External Switch selection. To operate in 4-step:
Select " WFS/Proced. A-B" in P025 to set up parameters for A and B
procedures.
Start the weld by pulling the gun trigger. The system will weld with
procedure A settings.
While welding, quickly release and then pull the gun trigger. The
system will switch to procedure B settings. Repeat to switch back to
procedure A settings. The procedure can be changed as many times
as needed during the weld.
Release the trigger to stop welding. When the next weld is made, the
system will start again with procedure A.