Econet Tm Variable Speed Outdoor Control (Vsodc); Board Features And Connections - Rheem P17 Series Installation Instructions Manual

Three stage r-410a heat pump outdoor units
Table of Contents

Advertisement

7.0 COMPONENTS & CONTROLS
7.7 EcoNet
7.7.1 Board Features and
Connections
(-)P17 heat pumps are equipped with a Variable
Speed Outdoor Control (VSODC) that interfaces
with the inverter, EcoNet
EcoNet
enabled air-handler or gas furnace using
TM
the EcoNet
serial communication protocol. The
TM
VSODC provides a low voltage terminal block
for control wiring and connections for various
sensors, controls, outdoor fan motor and inverter.
It also has a dual 7-segment LED for displaying
status and fault codes. Buttons are provided
for navigating the control menu and to initiate
and terminate various test modes. A plug-in
memory card provides model specific information
(model data) necessary for proper unit operation
and parameters for the correct indoor air-flow.
Dip switches are provided to allow adjustment
of the defrost termination temperature, outdoor
superheat setting, and number of EXV steps.
Colored LED's are provided to indicate if the EXV
is in the process of opening or closing.
The following is a list of features on the VSODC
and location of each.
1. Thermostat Terminals
2. Communication wire terminals
3. Modbus unitary inverter communication
connection
4. Outdoor PSC Fan relay connections
4
3
15
2
1
34
Variable Speed Outdoor Control (VSODC)
Control Center, and
TM
6
17
5
14
5. Outdoor ambient thermistor connection
6. Coil sensor (EVAPIN) and suction thermistor
(OST) connections
7. Liquid line (OLT – for future use) and
compressor sump (CPT) connections
8. Outdoor ECM fan PWM output connection
9. Suction pressure transducer (SPT) connection
10. Liquid pressure transducer (LPT) connection
(for future use)
11. Electronic expansion valve connection
12. Reversing Valve Connections
13. 3 Amp fuse
14. Test and SW2 Button
15. Communications LEDs (ET – EcoNet™
communication is transmitting; RT –
EcoNet™communication is receiving)
16. Memory card connection
17. Dual seven segment LED – Displays status,
diagnostic codes, fault recall, compressor
speed, superheat, and defrost menus
18. Dip Switches (Defrost [DFST] and EXV [EXV]
offset)
19. Dip Switches (EXV [1600/500] selection)
20. EXV Operational Lights (Green – EXV is
opening; Amber - EXV is closing)
CAUTION:
UNIT MAY START
SUDDENLY AND WITHOUT WARNING.
8
7
13
18
16
9
10
11
12
19
20