RUGGEDCOM RS900GPF
Installation Guide
Section 6.1.5
ISED
This device is declared by Siemens Canada Ltd to meet the requirements of the following ISED (Innovation Science
and Economic Development Canada) standard:
• CAN ICES-3 (A)/NMB-3 (A)
Section 6.1.6
RoHS
This device is declared by Siemens Canada Ltd to meet the requirements of the following RoHS (Restriction of
Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic
equipment:
• China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic Information Products
A copy of the Material Declaration is available online at
view/109738831.
Section 6.1.7
Other Approvals
This device meets the requirements of the following additional standards:
• EN50121-4
Railway applications – Electromagnetic Compatibility – Emission and Immunity of the Signaling and
Telecommunications Apparatus
Section 6.2
EMC and Environmental Type Tests
The RUGGEDCOM RS900GPF has passed the following Electromagnetic Compatibility (EMC) and environmental
tests.
EMC Type Tests
Test
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
ISED
Description
ESD
Radiated RFI
Burst (Fast Transient)
https://support.industry.siemens.com/cs/ww/en/
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
Test Levels
Severity Levels
± 8 kV
± 15 kV
20 V/m
± 2 kV
± 1.5 kV
Chapter 6
Certification
4
4
x
3
x
31