Ashly nX8004 Operating Manual page 34

Multi-mode power amplifiers 3,000w, 1,500w, 800w, and 400w per channel
Table of Contents

Advertisement

Operating Manual - nX, nXe, and nXp Power Amplifiers
Feedback Suppressor (Inputs only)
The Feedback Suppressor (FBS) provides automatic feedback control. This is done by constantly monitoring the audio and
automatically adjusting any one of 12 filters to remove feedback. Notch and Parametric Filter types are used, depending on the
characteristics of the feedback. Because feedback suppression is more effective on an single input rather than an output mix of
channels, the FBS is only available on inputs, and only at the 48 kHz sampling rate. The FBS is DSP resource-intensive, so if a
FBS is used, the FIR filter on the same channel's output gets disabled in order to allow the DSP power necessary for the FBS.
Filter Parameters
Filter (number) - Current Active Filter (highlighted).
Filter In/Out - Green = Filter In (engaged), Red = Filter Out (disengaged).
Filter Lock - Locks Filter at its current setting, when locked the detector will no longer adjust the filter.
Filter Mode - There are three filter modes:
Restricted: Filter will only broaden or deepen.
Floating: Detector may release filter after float time or modify filter type.
PEQ: Detector will not modify the filter however the user may control the filter.
Type - Selected Filter Type (Parametric or Notch).
Frequency - Selected Filter Center/Corner frequency.
Level - Selected Filter Boost/Cut amplitude.
Bandwidth - Selected Filter Bandwidth (or Q).
Feedback Detector Parameters
Sensitivity - Detector Sensitivity to feedback
Float Time - Time before a floating filter will start to release.