Ashly nX8004 Operating Manual page 28

Multi-mode power amplifiers 3,000w, 1,500w, 800w, and 400w per channel
Table of Contents

Advertisement

Operating Manual - nX, nXe, and nXp Power Amplifiers
Ambient Noise Compensation (output channels only)
Ambient Noise Compensation (ANC) is an automatic output level control that uses
a microphone to monitor background noise in a specific zone, then adjusts the out-
put level to that zone accordingly in order to maximize intelligibility. One amplifier
input channel must be dedicated to the sensing microphone and cannot be used for
other inputs.
nX amplifiers do not have mic preamps, so an external mic preamp is required. The
mic preamp output is then connected into any input on the nX amplifier other than
the program audio channel in which the ANC function is engaged on. The ambient
noise signal is then processed similar to a slow-responding SPL meter which is
then used as the control signal for the automatic level control of the program audio/
paging signal.
The ambient noise sensing microphone doesn't need to be a high-quality microphone
because it is only used to pick-up the overall noise level in the room and is not used
for the direct program audio or paging. The placement location of this noise-sensing
microphone is very important for the ambient noise compensation function to work
well. A unidirectional microphone pointed toward the noise sources and away from
the sound system speakers works best.
ANC Meters and Controls
Input Level Meter - The input level of the program audio before ANC gain/attenuation is applied.
Attenuation Meter - The gain/attenuation automatically applied to the program audio by the ANC function.
Max Gain - Sets the maximum gain that you allow the ANC to apply to the program audio. A typical starting value is 10 dB.
Min/Base Gain - Sets the minimum gain that you allow the ANC to apply to the program audio. A typical starting value is -20
dB. This also sets the starting gain value once the noise exceeds the threshold. The minimum gain is +1dB.
Gain Change Rate - The rate at which the ANC will change the gain as measured in seconds per dB. A typical starting value
is 2 seconds/dB.
Link Group - The channel group assignment for linking multiple channels parameters. Use this feature to link stereo program
audio channels to track each other in gain changes in response to ambient noise change.
Average Noise Meter - The level of the ambient noise signal at the point where it enters the matrix mixer and the ANC function.
Mixer Input Channel - The input channel selected for the ambient noise sensing microphone. The microphone signal is taken
at the point where it enters the matrix mixer, after any input signal path processing.
Noise Threshold - The noise-sensing signal level above which you desire the ANC to start to increase the program audio gain
above the Min Gain. A typical starting value is -30 dBFS. Keep in mind that any changes to the gain of the noise-sensing mi-
crophone will affect the setting of the Noise Threshold control.
Program/Ambient Gain Ratio - The ratio of dB increase in program level for every 1 dB increase in ambient noise level. A
typical starting value is 1.0 which means that for every 1 dB increase in ambient noise, the ANC will automatically increase
the gain of the program audio by 1 dB.