Ashly ne800 Operating Manual

Ashly ne800 Operating Manual

Network enabled two channel power amplifiers
Hide thumbs Also See for ne800:

Advertisement

Quick Links

Network Enabled
Two Channel Power Amplifiers
Operating Manual
ASHLY AUDIO INC.
847 Holt Road Webster, NY 14580-9103 Phone: (585) 872-0010
Toll-Free: (800) 828-6308 Fax: (585) 872-0739 ashly.com
ne800
ne800.10
ne800.70
ne800.25
ne1600
ne1600.10
ne1600.70
ne2400
ne2400.10

Advertisement

Table of Contents
loading

Summary of Contents for Ashly ne800

  • Page 1 Network Enabled Two Channel Power Amplifiers Operating Manual ne800 ne800.10 ne800.70 ne800.25 ne1600 ne1600.10 ne1600.70 ne2400 ne2400.10 ASHLY AUDIO INC. 847 Holt Road Webster, NY 14580-9103 Phone: (585) 872-0010 Toll-Free: (800) 828-6308 Fax: (585) 872-0739 ashly.com...
  • Page 2: Table Of Contents

    Operating Manual - NE Two Channel Power Amplifiers Important Safety Instructions Consignes de sécurité à lire attentivement The lightning flash with arrowhead symbol, within an equilateral triangle, Le symbole de la flèche dans un triangle équilateral symbolisant la foudre is intended to alert the user to the presence of uninsulated "dangerous est prévu pour sensibiliser l’utilisateur à...
  • Page 3: Introduction

    Ashly’s exclusive Five Year, Worry Free Warranty remains one of the most liberal policies available on any commercial grade product. The warranty covers every product with the Ashly brand name, and is offered at no extra cost to you, our customer.
  • Page 4 48kHz & 96kHz data rates are supported. 3) Network Digital Audio (CNM-2 or OPDante) - Ashly supports CobraNet and Dante network audio options which must be factory installed when purchasing the amplifier. CobraNet www.cobranet.info...
  • Page 5: Physical Description

    Operating Manual - NE Two Channel Power Amplifiers Protection This amplifier come standard with several protection circuits: Over Current Protection - Is controlled in the output stage. Thermal Protection - The amplifier senses output device temperature and adjusts a two-speed fan to keep the operating temperature within acceptable limits.
  • Page 6: Amplifier Rear Panel

    10. Remote Standby - Connect these two contact closure pins to remotely place the amp in standby. 11. Remote Level Control - These pins can be wired to remote potentiometers such as the Ashly WR-1 for level control of individual channels.
  • Page 7: Remote Amplifier Control

    3) FR-8/FR-16 Programmable Fader Controller - The FR-8 and FR-16 are Ethernet based programmable fader control- lers for networked Ashly products that have Protea DSP. Faders and LED buttons can be programmed for individual or group channel level control, matrix point level control, signal level display, mute, and A/B source selection. The FR remotes can be wall mounted in an electrical box, panel mounted, or freestanding, and have a back panel contact closure for a user lockout switch.
  • Page 8: Software

    - if two graphic equalizer blocks are “linked”, any change made to a control within either of the equalizers will result in an identical change to the other. Blocks may be linked within one Ashly device, or across multiple networked devices. Linking of multiple devices is managed through LINK GROUPS.
  • Page 9 Operating Manual - NE Two Channel Power Amplifiers The Amplifier Control Surface This is the main user interface for the NE two channel amplifier. Key features of this win- dow include: 1) Channel/Offset Link Group Faders - The level control provides up to 40dB of analog input attenuation.
  • Page 10 Operating Manual - NE Two Channel Power Amplifiers Protea Two Channel Amplifier DSP Control Surface (PE DSP option must be installed) The DSP Control Tab Extensive online help is available for all DSP functions. Look in the Protea software Help Menu/Contents and Index/Contents/ Protea NE Products/NE Amplifiers/DSP Control for details of all DSP functions.
  • Page 11: Specifications/Block Diagram

    6. SPECIFICATIONS GENERAL POWER AMPLIFIER SPECIFICATIONS Power Output Per Channel Low Z models, Stereo Mode, Both Channels Driven ....ne800 ne1600 ne2400 8Ω , 20Hz-20kHz 1%THD ........225W ..450W ..700W 4Ω...
  • Page 12 Operating Manual - NE Two Channel Power Amplifiers DSP SPECIFICATIONS (If Protea DSP is installed) EQUALIZATION Input: ....Active Balanced, 10k Ohms FIR Filter (Output only, 48kHz only, 2-384 Taps) Max Input Level: .
  • Page 13 Operating Manual - NE Two Channel Power Amplifiers TOOLS Audio Meter Range: ....-60dBu to +20dBu Increments:... . 1dB Peak Hold Indicator: .
  • Page 14 Operating Manual - NE Two Channel Power Amplifiers...
  • Page 15: Warranty Information

    Any implied warranties which may arise under the operation of state law shall be effective only for FIVE years from the original date of purchase of the product. ASHLY AUDIO, INC. shall be obligated to only correct defects in the product itself. ASHLY AUDIO, INC. is not liable for any damage or injury which may result from or be incidental to or a consequence of such defect. Some states do not allow limita- tions on how long an implied warranty lasts, or the exclusion, or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
  • Page 16 Fax: (585) 872-0739 Toll Free (800) 828-6308 ashly.com  2015 by Ashly Audio Corporation, a division of Jam Industries, Ltd. All rights reserved worldwide. Printed in USA r09 All features, specifications, and graphical representations are subject to change or improvement without notice.

Table of Contents