Operating Instructions - Crown EMT-6-6 Installation & Operation Manual

Direct steam kettles on electric boiler cabinet base
Hide thumbs Also See for EMT-6-6:
Table of Contents

Advertisement

INSTALLATION AND OPERATION MANUAL, DIRECT STEAM KETTLES MOUNTED ON
MODELS EMT-6, EMT-10, EMT-12, EMT-6-6, EMT-10-6, EMT-10-10

3.0 OPERATING INSTRUCTIONS

For CSD-1 equipped boilers, see section 4.0 CSD-1 Optional Feature for proper operating
instructions.
BOILER CONTROLS (Inside Cabinet)
Main Power Switch
Pilot Light
Boiler Pressure Gauge
Water Level Sight Glass - Observe level of water and water quality in the boiler. Murkiness in
Water Level Control
Safety Valve
OPERATION OF THE BOILER
Turn on water and power supply.
Open cabinet door and turn main power switch ON. Pilot light ignites and water begins to fill
boiler - observe water gauge sight glass to verify that proper water level is reached.
Once the proper water level is reached, the heaters begin to heat the water. Heaters require
about 15 minutes to begin steam generation. The boiler pressure gauge in the cabinet should
indicate steam pressure in a range of 9 to 11 psig.
PART NUMBER 10071R2
ELECTRIC BOILER BASE CABINET,
- ON fills the boiler tank and turns the boiler heaters on. You should
allow 20 minutes to fill the tank and generate steam.
- OFF shuts off the boiler heaters and opens the Automatic Blowdown
Valve, emptying the boiler tank and releasing water and steam to
the drain. This should be done daily to remove sediment, lime, or
scale.
- Indicates main power is ON.
- Should read 9 - 11 psig during operation; 0 psig during shutdown.
the water indicates inadequate water quality; the owner must supply
proper water to the boiler (see Water Quality Statement, page 4).
- While boiler is ON, briefly open the water level control valve once a
day to remove any sediment that might accumulate. (See page 15
for detailed instructions.)
- This valve will release (pop off) if the boiler has too much pressure.
Once a week, this valve should be tripped during operation to make
sure it functions properly.