Determine Vent Setup In The Combination Venting Unit; Install Non-Combustible Front Fireboard Standoff - Superior Fireplaces DRT Series Installation And Operation Instruction Manual

Direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRT/DRC3500 Series Direct-Vent Gas Fireplaces
Determining Vent Setup in the Combination Venting Unit
4.
Combination venting units are shipped with rear venting setup nearly ready for install. If this is the type of vent you require, remove
all insulation packing and flue plug block off from rear venting and proceed with fireplace installation.
If you require a top-vented unit, use the following steps to convert the fireplace before use.
Step 1: Remove the eight (8) screws
holding the top vent cover plate and
gasket.
Step 4: Make sure insulation disc is
still in the round cover. Remove the
flue plug from the top flue.
Installing Non-Combustible Front Fireboard Standoff
5.
A non-combustible standoff board is provided with the fireplace to prevent overlap of drywall or other material of portions of the
fireplace that may be prone to the buildup of heat. It is supported by a middle bracket and two side brackets.
Separate and note metal side
(2) and center (1) brackets.
Step 2: Remove the three screws that align with the clearance
screw holes from the top of the unit. Secure the center bracket
to the top center of the fireplace
20
Step 2: Remove the round flue
cover from the top venting outlet.
Step 5: Bend tabs out on round flue cover. Secure the round flue cover (provided) to
the wrapper over the rear venting outlet. Use two (2) 3/4" long sheet metal screws
Step 1: Remove two screws from the top and side of the unit. Bend the side bracket securing tab
over the edge of the unit and secure. Secure bracket to the top through the clearance screwhole.
Step 3: Top of front fireboard
standoff should be flush with
top standoffs (not shown).
Installation
900298-00, 06/2018
Step 3: Remove insulation from
inside flue pipe.
Step 4: Fireboard standoff
can be secured to the cap-
ture screwholes.