I. Construction and Water/Refrigeration Circuit Diagram
A. Construction
1. Air-Cooled (MAH)
Spray Tubes
Inlet Water Valve
Thermostatic
Bin Control
Pump Motor
Control Switch
Service Switch
Float Switch
Thermostatic Bin Control
Bracket & Bulb Holder
Drain Valve
Cleaning Valve
Control Box
Model Shown: KML-351MAH
Thermostatic
Expansion Valve
Water Supply Inlet
Compressor
Liquid Line Valve
Model Shown: KMD-460MAH
7
Hot Gas Valve
Condenser
Fan Motor
High-Pressure
Switch
Drier
Mechanical Bin Control
and Bracket