6. KML-250MAH

Specification Sheet
AC SUPPLY VOLTAGE
AMPERAGE
MINIMUM CIRCUIT AMPACITY
MAXIMUM FUSE SIZE
ELECTRIC & WATER CONSUMPTION
ELECTRIC
W (kWH/100 lbs.)
WATER gal./24HR (gal./100 lbs.)
ICE PRODUCTION PER CYCLE
BIN CONTROL SYSTEM
REFRIGERANT CHARGE
Performance Data Sheet
APPROXIMATE ICE PRODUCTION PER
24 HR.
lbs./day kg./day
APPROXIMATE ELECTRIC
CONSUMPTION
watts
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
3
gal./day
m
/day
FREEZING CYCLE TIME
min.
HARVEST CYCLE TIME
min.
HEAD PRESSURE
2
PSIG
kg/cm
G
SUCTION PRESSURE
2
PSIG
kg/cm
G
TOTAL HEAT OF REJECTION
115/60/1
8.2A (5 Min. Freeze AT 104°F/WT 80°F)
20 A
20 A
90/70°F
70/50°F
813 (8.2)
755 (5.9)
84 (35.2)
194 (63.1)
6.6 lbs. (3.0 kg) 360 pcs.
Thermostatic Bin Control
R-404A,
1 lb. 2 oz. (505 g)
AMBIENT TEMP.
(ºF/ºC)
50/10
70/21
307
80/27
292
90/32
287
100/38
260
70/21
755
80/27
768
90/32
772
100/38
791
70/21
194
80/27
169
90/32
162
100/38
124
70/21
80/27
90/32
100/38
4.7
70/21
80/27
4.1
90/32
4.0
100/38
3.2
70/21
247
80/27
261
90/32
266
100/38
295
58
70/21
80/27
59
90/32
59
100/38
61
62
WATER TEMP. (ºF/ºC)
70/21
139
287
130
132
260
118
238
130
108
118
234
106
772
794
813
814
0.73
162
0.61
0.64
119
0.45
84
0.61
0.32
0.47
81
0.31
27
29
29
32
29
35
33
36
4.0
3.0
2.2
2.2
17.4
266
18.7
18.4
290
20.4
18.7
311
21.9
20.7
318
22.3
4.1
59
4.2
4.1
61
4.3
4.2
62
4.4
4.3
62
4.4
5560 BTU / hr [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
90/32
267
121
245
111
220
100
204
93
779
792
815
816
142
0.54
114
0.43
72
0.27
61
0.23
32
35
38
41
3.7
3.1
2.1
2.0
293
20.6
319
22.4
340
23.9
366
25.7
60
4.2
62
4.3
63
4.4
64
4.5
ENG.F-011.0.1196