Troubleshooting

Related Messages

When the unit's power is ON, messages such as those shown below may be displayed. When any
such message is displayed on the screen, please respond as described below. If the same message is
displayed after the treatment, or if a message other than the following appears, please contact your
dealer or service company.
Message
TO MAXIMIZE PERFORMANCE,
LAMP REPLACEMENT IS RECOM-
MENDED.
CLEAN THE AIR FILTER
AFTER CLEANING AIR FILTER,
RESET THE FILTER TIMER.
NO INPUT IS DETECTED
ON ***
SYNC IS OUT OF RANGE
ON ***
CHECK THE AIR FLOW
CLEAN THE AIR FILTER
POWER OFF FIRST,
THEN CLEAN THE AIR FILTER.
AFTER CLEANING THE AIR FIL-
TER, RESET THE FILTER TIMER.
Note:
* Although this message will be automatically disappeared after around 3 minutes, it will be
reappeared every time the power is turned ON.
35
ViewSonic PJ510
The unit does not display a warning message on the screen when
the lamp expires or fails. When the lamp does not light, this indi-
cates that the lamp is no longer functional and should be replaced.
Replace the lamp and do not forget to reset the timer.
A note of precaution when cleaning the air filter.
After cleaning the filter, operate FILTER TIME of the OPTION Menu,
then perform reset of the filter timer.
There is no input signal.
Check the signal input connection and the status of the signal
source.
The horizontal or vertical frequencies of the inputted signal is out-
side of the operating range limits of this unit. Please confirm the
specs for this unit or the signal source specs.
The internal temperature is rising. Please turn the power OFF, then
allow the unit to cool down for approximately 20 minutes. After hav-
ing confirmed the following items, then please reset the power to
ON.
• Is there blockage of the air filter?
• Is the air filter dirty?
• Does the ambient temperature exceeds 35°C?
A note of precaution when cleaning the air filter.
Please immediately turn the power off, and clean or change the air
filter by referring to the "Air Filter" section of this manual. After you
have cleaned or changed the air filter, please be sure to reset the fil-
ter timer.
If the same message is displayed after the treatment, please clean
the transparent area of filter cover and the dust-detecting window,
according to the following.
Description