OBSERVED PROBLEM
Gas odor even when gas control valve is off
Gas odor during combustion
Glass soots
Dark residue on inside of fireplace
126718-01J
TROUBLESHOOTING Continued
POSSIBLE CAUSE
1. Gas leak. See Warning statement at top
of Page
2. Control valve defective
1. Foreign matter between control valve and
burner
2. Gas leak. See Warning statement at top
of Page
1. Debris around burner air mixer
2. Improper vent configuration
1. Air holes at burner inlet blocked
2. Burner flame holes blocked
3. Improper venting or excessive blockage
Superiorfireplaces.us.com
REMEDY
1. Locate and correct all leaks (see Checking
Gas Connections, Page 26)
2. Replace control valve
1. Take apart gas tubing and remove foreign
matter
2. Locate and correct all leaks (see Checking
Gas Connections, Page 26)
1. Inspect opening at base of burner to see
that it is NOT packed with any type of
material
2. Check vent configuration specification
(see Venting Installation, Page 13)
1. Clean out air holes at burner inlets. Peri-
odically repeat as needed
2. Remove blockage
3. Have vent system inspected, including
termination cap. Remove any restrictions
or obstruction