Superior Fireplaces DRL4543TEN Installation And Operation Instruction Manual page 16

Direct-vent linear gas fireplace
Table of Contents

Advertisement

*Use silicone caulking to
seal the top and sides of
the termination, up to the
underlayment, stucco, or
masonry wall surface.
*Caulk
*Caulk
Stucco
Figure 10 - Venting Connection and Exterior Wall Recessing of the Horizontal Compact Termination (SV4.5HTKCT)
Vent Components Required
Termination Kit Only
Termination Kit and 6" Vent Section
(SV4.5L6)
Termination Kit and 12" Vent Section
(SV4.5L12)
Termination Kit and Telescopic Section
(SV4.5LA) and 6" vent section (SV4.5L6)
Table 1: Venting Components Required for Various Exterior Wall
Thicknesses, when using Typical Termination Kits
NOTE: See Table 1 for wall thickness ranges when using SV4.5HTKCT
termination kit.
16
VENTING INSTALLATION Continued
Interior Surface of
Finished Wall
Maximum Extent of
Vent Run Sections
Siding
Relative to Exterior
Surface of Framing
Last Vent Section. Use
T e l e s c o p i c
V e n t
Section (SV4.5LA), If
Necessary
Adaptor
SV4.5RCH
Exterior Wall Thickness
6 to 9-1/4" (152–235 mm)
10-3/4 to14" (273–356 mm)
16-3/4 to 20" (426–508 mm)
11-3/4 to 20" (299–508 mm)
Superiorfireplaces.us.com
Maximum wall thickness
9-1/4" (235 mm)**
Exterior Surface of Siding
Exterior Surface of
Framing
6" to 9-1/4"
(152 to 235 mm)**
1-1/4" Maximum Recess of
the Square Termination into
Exterior Finishing Material
Model
SV4.5L6
SV4.5L12
SV4.5L24
SV4.5L36
SV4.5L48
Table 2: Effective Vent Length
Effective Length
4-1/2" (115 mm)
10-1/2" (267 mm)
22-1/2" (572 mm)
34-1/2" (877 mm)
46-1/2" (1181 mm)
126718-01J