Propane/LP
Supply Tank
Figure 27 - External Regulator with Vent Pointing Down
(Propane/LP Only)
Check your building codes for any special requirements for locating
equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will prevent
excess sealant from going into pipe. Excess sealant in pipe could
result in clogged fireplace valves.
WARNING: Use pipe joint sealant that is resistant
to liquid petroleum (LP) gas.
We recommend that you install a sediment trap/drip leg in supply
line as shown in Figure 28. Locate sediment trap/drip leg where it is
within reach for cleaning. Install in piping system between fuel supply
and fireplace. Locate sediment trap/drip leg where trapped matter is
not likely to freeze. A sediment trap traps moisture and contaminants.
This keeps them from going into fireplace gas controls. If sediment
trap/drip leg is not installed or is installed wrong, fireplace may not
run properly.
Gas Shutoff Valve
1/2" NPT
Incoming Gas
Line
126718-01J
FIREPLACE INSTALLATION Continued
External Regulator with
Vent Pointing Down
Flexible Gas Line
Do NOT Kink
NOTE:
1) Wire connections not shown for clarity
2) * 1/8" NPT Plugged Tapping
Figure 29 - Connecting Incoming Gas Line to Flex Gas Line
Superiorfireplaces.us.com
Equipment Shutoff Valve
with 1/8" NPT Tap*
Approved
Flexible Gas
Line
* The equipment shutoff valve may be supplied with the
appliance or you can purchase it from your retailer.
CONNECTING FIREPLACE TO GAS SUPPLY
Installation Items Needed
• 5/16" hex socket wrench or nut-driver
• Sealant (resistant to propane/LP gas, not provided)
1. Route flexible gas line (provided by installer) from equipment
shutoff valve to fireplace. Route flexible gas supply line through
one of the access holes on side of fireplace.
2. Attach flexible gas line from gas supply to control valve (see Figure
29).
3. Check all gas connections for leaks. See Checking Gas Connec-
tions, Page 26.
Inlet Pressure Tap
Pilot Adjustment
Outlet Pressure Tap
Natural - From Gas
Meter (5.5" W.C. to
10.5" W.C. Pressure)
Propane/LP From
External Regulator
(11" W.C. to 14" W.C.
3" (77 mm)
Pressure)
Minimum
Cap
Pipe
Tee
Joint
Nipple
Sediment Trap/Drip
Leg
Figure 28 - Gas Connection
Set Screw