Superior Fireplaces DRL4543TEN Installation And Operation Instruction Manual page 22

Direct-vent linear gas fireplace
Table of Contents

Advertisement

PARTS LIST FOR VENTING KITS AND COMPONENTS
Catalog
Model
Number
F1797
SV4.5HTKCT
F1798
SV4.5HTKCT20
94L10
SV4.5HTSS
H1968
SV4.5HT-2
H2152
SV4.5CGV-1 Vertical Termination Cap, High Wind
Vent Sections (Rigid)
77L70
SV4.5L6
77L71
SV4.5L12
77L72
SV4.5L24
77L73
SV4.5L36
77L74
SV4.5L48
77L75
SV4.5LA
The following flashing comes packaged with a storm collar
77L78
SV4.5F
77L79
SV4.5FA
77L80
SV4.5FB
77L81
SV4.5SC6
H6183
SV4.5HF5
H2246
SV4.5HF-10
H2247
SV4.5VF-10
96K92
SV4.5SP
77L76
SV4.5E45
77L77
SV4.5E90
*All compressed flex vents can be expanded up to two times.
22
VENTING INSTALLATION Continued
IMPORTANT NOTE: The installation accessories shown in this section are part
of the safety agency listing for the product models represented in this manual.
Table 3: Listed Components
Description
Rigid, Horizontal, Compact Termina-
tion with Firestop/Spacer (H2246),
Adaptor (74L61) (see 750204M)
Rigid, Horizontal Compact Termina-
tion, 20" with Shield and Firestop
(see 750247M and 750204M)
Small Square Termination, Horizontal
- Rigid
Horizontal Termination, Kit
6" (152 mm)
12" (305 mm)
24" (610 mm)
36" (914 mm)
48" (1219 mm)
Telescopic Length Slip Section
(2–7 1/2" rigid)
Flat Roof Flashing
1/12 to 7/12 Adjustable Flashing
7/12 to 12/12 Adjustable Flashing
Storm Collar (6 pack)
Firestop Spacer, 5", rigid
Firestop/Spacer-Horizontal, rigid
(3-1-1 spacing), 10 Pack
Firestop/Spacer-Vertical, rigid
(1-1-1 spacing), 10 Pack
Support Plate
Elbows
45° Elbow
90° Elbow
Superiorfireplaces.us.com
Listed Secure Flex
These termination kits include firestop/spacer, gear clamps, and
flex adaptor.
60L10
SF-18
98K03
SF-12
F1803
SF4.5HTKCT
F1799
SFKIT18CT
F1800
SFKIT24CT
F1801
SFKIT36CT
F1802
SFKIT48CT
91L66
SFGC4-6
91L67
SFGC7-6
56L74
SFVT30
56L75
SFVT45
H7748
H7748
F3191
SV4.5AdaptorKit
Components
®
18 ft (5.49 m) compressed flex*
(see 750053M)
12 ft (3.66 m) compressed flex*
(see 750052M)
Horizontal Compact Termination for
flex (without flex)
Compact Termination for flex with 18"
(457 mm) compressed flex
Compact Termination for flex with 24"
(610 mm) compressed flex
Compact Termination for flex with 36"
(914 mm) compressed flex*
Compact Termination for flex with 48"
(1219 mm) compressed flex*
Gear Clamp 4.5" (114 mm) for flex
(6-pack)
Gear Clamp 7.5" (190.5 mm) for flex
(6 pack)
Vertical Termination for flex (flat to
6/12) with flex adaptor, section of
rigid vent, roof support collar assem-
bly, roof flashing and storm collar.
(see 750052M)
Vertical Termination for flex (6/12 to
12/12) with flex adaptor, section of
rigid vent, roof support collar assem-
bly, roof flashing and storm collar.
(see 750052M)
36" Flex Connector Kit.
36" of flex with two adaptors for mat-
ing two rigid sections of vent together.
Secure Flex Adaptor Kit
Includes rigid to flex adaptor and flex to
rigid adaptor
(flex not included)
126718-01J