Fe36 (Analog Input Value Vi/Ii); Fe37 (Rx Input); Fe60 - Fe63 (My Monitor); Fe14 (Cumulative Run Time) - Toshiba PDP002Z Function Manual

Profibus-dp option
Table of Contents

Advertisement

4.2.11.

FE36 (Analog input value VI/II)

The value inputted into the VI/II terminal is read.
The value range is 0 - 10000 (0 - 100.00 %).
Also the same as the parameter FE35 (RR Input).
4.2.12.

FE37 (RX Input)

The value inputted into the RX terminal is read.
The value range is -10000 - 10000 (-100.00 - +100.00 %).
4.2.13.

FE60 - FE63 (My Monitor)

Refer to the function Manual (E6581335).
4.2.14.

FE14 (Cumulative run time)

The operated cumulative time is read by the hexadecimal number.
For example, when cumulative operation time is 18 hours, 0x12 (16 hours) is read.
0x12 (Hex.) = 18 (Dec., hour)
4.2.15.

FE40 (Analog output (FM))

The output value of FM terminal is read.
The value range is set to 0 - 65535 (0xFFFF).
- Also about FE41 (AM terminal output monitor), it is the same as this parameter.