Performance Data - Pentair FRESHPOINT GRO-475M Installation And Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

PERFORMANCE DATA

IMPORTANT:
Read this performance data and compare the capabilities of
this system with your actual water treatment needs.
It is recommended that before installing a water treatment
system, you have your water supply tested to determine your
actual water treatment needs.
This system has been tested according to NSF/ANSI 58 for the
reduction of substances listed below. The concentration of the
indicated substances in water enteringthe sysem was reduced
to a concentration less than or equal to the permissible limit
for water leaving the system as specified in NSF/ANSI 58.
The GRO-475B/GRO-475M shall only be used for arsenic
reduction on chlorinated water supplies containing detectable
residual free chlorine at the system inlet. Water systems using
an in-line chlorinator should provide a one-minute chlorine
contact time before the RO system.
Do not use with water that is microbiologically
WARNING:
unsafe or of unknown quality without adequate disinfection
before or after the system. Systems certified for cyst reduction
may be used on disinfected waters that may contain filterable
cysts.
NOTE: Substances reduced are not necessarily in your water.
Filter must be maintained according to manufacturer's
instructions, including replacement of filter cartridges.
The tested efficiency rating for these systems is 22.05%.
Efficiency rating means the percentage of the influent water
to the system that is available to the user as reverse osmosis
treated water under operating conditions that approximate
typical daily usage.
The tested recovery rating is 38.65%. Recovery rating means
the percentage of the influent water to the membrane portion
of the system that is available to the user as reverse osmosis
treated water when the system is operated without a storage
tank or when the storage tank is bypassed.
The GRO-475B/GRO-475M has been tested for the treatment
of water containing pentavalent arsenic [also known as As(V),
As(+5), or arsenate] at concentrations of 0.050 mg/L or less.
This system reduces pentavalent arsenic, but may not remove
other forms of arsenic. This system is to be used on water
supplies containing a detectable free chlorine residual or on
water supplies that have been demonstrated to contain only
pentavalent arsenic. Treatment with chloramine (combined
chlorine) is not sufficient to ensure complete conversion
of trivalent arsenic to pentavalent arsenic. Please see the
Arsenic Facts section of the Performance Data Sheet for
further information.
EPA # 082989-CHN-001
System Production Rate:
Recovery Rating:
Efficiency Rating:
TDS Rejection:
System Tested and Certified by NSF International
against NSF/ANSI Standard 42, 53, 58, and CSA
B483.1 for the reduction of the claims specified on the
Performance Data Sheet.
C
US
21.08 gpd (79.77 Lpd)
41.05%
23.57%
96.3%
FRESHPOINT GRO-475B/GRO-475M Installation and Operation Manual • 17
GRO-475B/GRO-475M SYSTEM INSTALLED
WITH FDF1-RC, GRO75-RC, F1B1-RC,
F1GC-RC FILTER CARTRIDGES
Model GRO-475B / GRO-475M
Influent Challenge
Substance
Concentration
Standard 42
Chlorine
2.0 mg/L ± 10%
Taste and Order
Standard 53
Cysts*
Minimum 50,000/L
Atrazine
0.009 mg/L ± 10%
Lead (pH 6.5)
0.15 mg/L ± 10%
Lead (pH 8.5)
0.15 mg/L ± 10%
Lindane
0.002 mg/L ± 10%
Standard 58
Total Dissolved Solids 750 ± 40 mg/L
Pentavalent Arsenic
0.050 mg/L ± 10%
Fluoride
8.0 mg/L ± 10%
Cysts*
Minimum 50,000/mL
Turbidity
11 mg/L ± 1 NTU
Lead
0.15 mg/L ± 10%
Selenium
0.10 mg/L ± 10%
Copper
3.0 mg/L ± 10%
Cadmium
0.03 mg/L ± 10%
Hexavalant Chromium 0.3 mg/L ± 10%
Trivalent Chromium
0.3 mg/L ± 10%
Radium 226/228
25 pCi/L ± 10%
Barium
10.0 mg/L ± 10%
* NSF/ANSI Standard 53 and 58 certified to reduce cysts such as Cryptosporidium and Giardia by
mechanical means.
Max Permissible
Product Water
Reduction
Average
Concentration
Requirements
Reduction
≥50%
95.9%
99.95%
99.99%
0.003 mg/L
93.7%
0.010 mg/L
99.9%
0.010 mg/L
99.6%
0.0002 mg/L
97.4%
187 mg/L
96.3%
0.010 mg/L
88.0%
1.5 mg/L
93.6%
99.95%
99.99%
0.5 NTU
>99.1%
0.010 mg/L
98.6%
0.05 mg/L
97.9%
1.3 mg/L
98.5%
0.005 mg/L
99.1%
0.1 mg/L
96.4%
0.1 mg/L
98.2%
5 pCi/L
80.0%
2.0 mg/L
96.3%

Advertisement

Table of Contents
loading

This manual is also suitable for:

Freshpoint gro75-rcFreshpoint gro-475bFreshpoint gro-47m

Table of Contents