Pentair FULLFLOXF C Series Installation And User Manual

Cartridge filter

Advertisement

Quick Links

FULLFLO
CARTRIDGE FILTER
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
Pressurized air can cause the lid to separate from the tank with great force. To reduce the risk of
severe injury or death, relieve pressure by opening air relief valve before opening filter. Before starting
the pump after servicing, ensure that clamp band is correctly fastened. See Important Warnings and
Safety Instructions (page i) and follow all instructions exactly; including the Opening the Filter (page 5),
Installing the Filter Lid and Clamp Ring (page 6), and Start-Up Instructions (page 7).
XF
®
C-SERIES
SAVE THESE INSTRUCTIONS
INSTALLATION AND
USER'S GUIDE

Advertisement

Table of Contents
loading

Summary of Contents for Pentair FULLFLOXF C Series

  • Page 1 ® FULLFLO C-SERIES CARTRIDGE FILTER INSTALLATION AND USER’S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Pressurized air can cause the lid to separate from the tank with great force. To reduce the risk of severe injury or death, relieve pressure by opening air relief valve before opening filter. Before starting the pump after servicing, ensure that clamp band is correctly fastened.
  • Page 2 Pressurized This guide provides installation and operation instructions for air can cause the lid to separate which can result in this product. Consult Pentair with any questions regarding this severe injury, death, or property damage. equipment.
  • Page 3 IMPORTANT: Keep all warning labels in good condition. If any warnings pressure has been discharged from the valve and a steady stream labels are damaged, missing, or become illegible call Pentair Customer of water appears. Observe filter pressure gauge and be sure it is not Service at 1-800-831-7133 and request replacement labeling.
  • Page 4: Table Of Contents

    CUSTOMER SERVICE / TECHNICAL SUPPORT If you have questions about ordering Pentair replacement parts, and pool products, please contact: Customer Service and Technical Support, USA Sanford, North Carolina (8 A.M. to 4:30 P.M. ET) (8 A.M. to 4:30 P.M. — Eastern/Pacific Times)
  • Page 5: General Information

    GENERAL INFORMATION THIS SYSTEM OPERATES UNDER HIGH PRESSURE. When any part of the circulating system (e.g., Clamp Ring, Pump, Filter, Valves, etc.) is serviced, air can enter the system and become pressurized. Pressurized air can cause the lid to separate which can result in serious injury, death, or property damage.
  • Page 6: Installation

    INSTALLATION This filter must be installed by a qualified pool technician in accordance with all applicable local codes and ordinances. Improper installation could result in death or serious injury to pool users, installers, servicers, or others and may also cause damage to property. For Installation of Electrical Controls at Equipment Pad (ON/OFF Switches, Timers, Control Systems and Automation) Install all electrical controls at the equipment pad, such as ON/OFF switches, timers, control systems, etc.
  • Page 7: Installing The Manual Air Relief Valve

    Installing the Manual Air Relief Valve The manual air relief valve and pressure gauge are included with this filter to help ensure safe operation of the equipment. Always Figure 2 maintain these components in good working condition. PRESSURE GAUGE 1. Remove the HiFlow™ Manual Air Relief Valve and the pressure gauge from the accessories package included with your FullFloXF ®...
  • Page 8: Anchor Clamp Installation

    Anchor Clamp Installation Installation of anchor clamps is recommended in high wind and seismically active areas. A Pentair Anchor Clamp Kit (P/N 178840) is not included with this filter, but can be purchased separately. Anchor clamps hold the FullFloXF C-Series Cartridge ®...
  • Page 9: System Start-Up And Operation

    SYSTEM START-UP AND OPERATION The following information should be read carefully since it outlines the proper manner of care and operation for your filter system. As a result of following these instructions and taking the necessary preventative care, you can expect maximum efficiency and life from your filtration system.
  • Page 10: Installing The Filter Lid And Clamp Ring

    Installing the Filter Lid and Clamp Ring Follow these instructions exactly to prevent the lid from separating from the filter during system start-up or operation. (See Important Warnings and Safety Instructions, page i-ii). REQUIRED TOOLS: • Ratchet Wrench • 7/8" Socket Clamp Ring, Hand Tighten Open Position...
  • Page 11: Start-Up Instructions

    If any of these conditions exist, shut off the pump immediately. Open the manual air relief valve to relieve pressure and clean the valve (see Cleaning Open Position the Manual Air Relief Valve, page 8). If the problem persists, call Pentair Figure 8 Technical Service at (800) 831-7133 for assistance.
  • Page 12: Maintenance

    MAINTENANCE FILTER OPERATES UNDER HIGH PRESSURE. When any part of the circulating system, (e.g., clamp, pump, filter, valve(s), etc.), is serviced, air can enter the system and become pressurized. Pressurized air can cause the lid to separate which can result in severe injury, death, or property damage.
  • Page 13: When To Clean The Filter

    When to Clean the Filter Properly monitoring and cleaning the filter will prevent avoidable repairs and maintenance. Clean your filter when pressure reads between 8-10 psi higher than the “Original Starting Pressure” recorded in Table 2 on page 7, or when significant reduction in flow is noticed. The pressure reading increases as it filters dirt from your pool.
  • Page 14: Acid Soaking The Filter Cartridges

    Acid Soaking the Filter Cartridges After an extended period of operation, it may be necessary to soak the filter cartridges in an acid solution. Acid soaking will remove algae, calcium carbonate, iron and other mineral build-ups from the cartridges. If not removed, these mineral deposits can lead to the restriction of water flow through the FullFloXF C-Series Cartridge Filter and can ®...
  • Page 15: Replacing Filter Cartridges

    Replacing Filter Cartridges Figure 13 Filter cartridge life will vary with pool conditions such as bather load, wind, dust, etc. You can expect an average cartridge life of three (3) years under normal conditions. To replace filter cartridges: 1. Follow Opening the Filter exactly (page 5). 2.
  • Page 16: Troubleshooting

    TROUBLESHOOTING Air entering the system can cause the lid to separate from the filter. If the below symptoms are observed, do not attempt to remove or tighten the clamping system or perform any other servicing until you have shut off pump and relieved all air and pressure in accordance with the Opening the Filter instructions (page 5).
  • Page 17: Technical Data

    TECHNICAL DATA Dimensional Drawings 22.5” 57.2 cm DIM “A” MODEL DIM "A" C420 42.6" (108.2 cm) 23.5” 56.7 cm C520 55.6" (141.2 cm) 23” C620 55.6" (141.2 cm) 58.4 cm 15.5” 39.4 cm 21.5” 54.6 cm Head Loss Comparison Curve Head Loss Curves Flow Rate (gpm) Recommended Flow Rates...
  • Page 18: Replacement Parts

    REPLACEMENT PARTS Quantity by Model Number Item Part Description 160449 160430 160448 (C420) (C520) (C620) Pressure Gauge 190058 Pressure Relief Valve 98209800 Tank Lid, Short 178832 Tank Lid, Tall 178833 Air Bleed Screen Cap 190106z Top Manifold Kit 178838 O-Ring, Manifold 192323 170104 Filter Cartridge...
  • Page 19 NOTES XF® FULLFLO C-SERIES Cartridge Filter Installation and User’ s Guide...
  • Page 20 WWW.PENTAIR.COM All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered trademarks and logos are the property of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.