DT-4500 Series C- and Ku-Band Down Converters
Ethernet Interface Operation
7.3.1.1 Configure HyperTerminal for Telnet Remote Control
Operation

Figure 7-3. Configure HyperTerminal

See Figure 7-3. Do these steps:
• Make sure to define the Connect To Telnet connection properties
correctly (File  Properties) (Figure 7-3, left):
a. Enter the unit's Traffic/Management IP Address as the "Host
address" (e.g., 192.168.1.1).
b. Enter TCP Port 23
c. Set "Connect using" to TCP/IP (Winsock) instead of COM1 or
COM2.
d. Click [OK] to save your settings.
For ASCII Setup (File  Properties  Settings  ASCII Setup) (Figure
7-3, right):
a. Check the "Send line ends with line feeds" option in the 'ASCII
Sending' section.
b. Check the "Append line feeds to incoming line ends" option in
the 'ASCII Receiving' section.
c. Click [OK] to save your settings.
as the "Port number".
7–6