Mitsubishi Electric Mr.SLIM PEH Series Technical & Service Manual page 57

Split-type, heat pump air conditioners
Table of Contents

Advertisement

4. MULTIPLE REMOTE CONTROLLER ADAPTER
This adapter is needed for remote indication (operation/check). Adapter connection is described on No. OCT01.
Part No.
1
2
3
4
5
5. CENTRALIZED REMOTE CONTROLLER
Allows individual or combined control of up to 16 units. When using the PAC-805RC, the program timer adapter (PAC-
825AD)is also needed. See page 59.
Part No.
5-1. Dimensions
E N G A G E D
G R O U P
1 2 3 4 5 6 7 8 9 10
G R O U P
S E L E C T I O N
P R O G R A M
A C T I V E B Y P A S S
T I M E R
C O N T R O L L E R
D U A L C E N T R A L
O P E R A T I O N
CENTRAL
MITSUBISHI ELECTRIC
1 1 7
5-2. Functions
"ENGAGED" indicator
When this indicator is lit, transmission is in
progress and all switches are inoperative.
DUAL/CENTRAL switch
This change-over switch governs the oper-
ation of the accessory remote controller.
"DUAL"
Instructions from both the accessory
remote controller and the centralized
remote controller are valid. (Priority given
to the last instruction received.)
"CENTRAL"
ON/OFF switching by the accessory
remote controller is invalidated. Operation
is controlled by the centralized remote con-
troller only.
Initial setting is "DUAL".
LCD Matrix Display
This display indicates the operational sta-
tus of all connected units either by steady
lighting or by flashing.
Independent "DUAL / CENTRAL" and "ACTIVE / BYPASS" setting of all the groups is possible. When the power supply to the
centralized remote controller is cut due to power failure, all settings will return to the original "DUAL" and "BYPASS".
PAC-SA88HA-E
BRN
RED
ORN
YLW
GRN
PAC-805RC
1 2
POWER
ON/OFF
AHEAD
BACK
ACTIVE
BYPASS
DUAL
1 1 3
2 3 . 5
E N G A G E D
G R O U P
1 2 3 4 5 6 7 8 9 10
G R O U P
BACK
S E L E C T I O N
P R O G R A M
ACTIVE
A C T I V E B Y P A S S
T I M E R
BYPASS
C O N T R O L L E R
DUAL
D U A L C E N T R A L
CENTRAL
O P E R A T I O N
10 9 8 7 6 5 4 3 2 1
POWER
E N G A G E D
ON/OFF
G R O U P
1 2 3 4 5 6 7 8 9 10
G R O U P
AHEAD
BACK
S E L E C T I O N
P R O G R A M
ACTIVE
A C T I V E B Y P A S S
T I M E R
BYPASS
C O N T R O L L E R
DUAL
D U A L C E N T R A L
CENTRAL
O P E R A T I O N
MITSUBISHI ELECTRIC
5 6 . 3
1 1
POWER
ON/OFF
AHEAD
POWER ON/OFF switch
Operation ON/OFF switch.
BACK
AHEAD buttons
These buttons are used to designate
the attached unit(s). (They designate
the unit to be centrally controlled.)
When group "00" is designated; col-
lective ON/OFF instruction is sent to all
units.
When group "01"-"16" is designated;
ON/OFF instruction is sent to the des-
ignated units only.
ACTIVE/BYPASS switch
This is a change-over switch for the
program timer.
(It selects timer operation on the pro-
gram timer.)
Use "BYPASS" when a program timer
is not connected.
"ACTIVE"
The switch tums ON/OFF operational
instructions from the program timer
automatically.
"BYPASS"
ON/OFF Operation is by the central-
ized remote controller only.
Initial setting is "BYPASS".
Unit : mm