Display
CENTRALLY
CONTROLLED display
This indicates when the unit is con-
trolled by optional features such as
central control type remote controller.
w display
This indicates when the continous
operation and time operation modes
are set.
It also display the time for the timer
operation at the same time as when
it is set.
OPERATION MODE display
This indicates the operation mode.
STANDBY display
This indicates when the standby
mode is set from the time the sleep
operation starts until the heating air
is discharged.
DEFROST display
This indicates when the defrost oper-
ation is performed.
CHECK display
This indicates when a malfunction
has occurred in the unit which should
be checked.
Caution
Only the
display lights when the unit is stopped and power supplied to the unit.
When power is turned ON for the first time the (CENTRAL CTRL) display appears to go off momentarily but this is not a
malfunction.
When the central control remote control unit, which is sold separately, is used the ON-OFF button, a button and
i TEMP button do not operate.
"NOT AVAILABLE" is displayed when the k button and j button are pressed.This indicates that this room unit is not
equipped with the fan direction adjustment function and the louver function.
r display
The current time , start time and stop
time can be displayed in tensecond
intervals by pressing the time switch
button. The start time or stop time is
always displayed during the timer
operation.
050
88
°C display
This displays the selected setting
temperature.
In this display example on the bottom left, a condi-
tion where all display lamps light is shown for
explanation purposes although this differs from
actual operation.
l display
The selected fan speed is displayed.
FILTER
CHECK MODE
TEST RUN
/ display
This lamp lights when electricity is
supplied to the unit.
88
°C display
The temperature of the suction air is
displayed during operation. The dis-
play range is 8° to 39°C. The display
flashes 8°C when the actual temper-
ature is less than 8° and flashes
39°C when the actual temperature is
greater than 39°C.
Operation lamp
This lamp lights during operation,
goes off when the unit stops and
flashes when amalfunction occurs.
CHECK MODE
display
TEST RUN
This display lights in the check mode
or when a test operation is per-
formed.