9.0

Operating Instructions

The spa control system has automatic functions that operate upon startup
and normal operation to protect the system. Upon power up, the readout
displays the following information:
1. Control panel displays current software release (e.g. 3.57).
2. Control panel displays "888" and all indicator LEDs are lit,
permitting visual inspection of all display segments and indi-
cator lights for proper operation.
3. After the initial start-up sequence ends, the actual water
temperature is displayed. If water temperature at this time
is less than the factory default temperature setting of 100°F
(38°C) and the spa is set to either of the standard filtration/
heating modes (page 30), the heater will turn on and run until the water
temperature rises to the factory setting, then turn off.
Note: It is common for the heater to turn on after the spa is first filled
because tap water is often very cold.
4. Approximately two minutes after power is applied to the spa, the first
filtration/heating cycle turns on pump 1. In Certa/Chelsee/Hamilton
models, an automatic five minute "blow-out" function also activates
pump 2 for a period of five minutes to flush all lines. Then, after five
minutes, pump 2 turns off and pump 1 continues to operate for the
duration of the cycle.
Note: This function only occurs during the first filtration/heating cycle each
day.
9.1

Setting Water Temperature

The spa's thermostat provides optimum control of water tem-
perature. The temperature setpoint (set temperature) can be
adjusted from 65-104°F (18-40°C). To raise the set temperature,
press the WARMER (
the COOLER (
set temperature. To access the overtemp
feature that allows the spa to reach 106°F
(41°C) follow the steps below (Figure 1).
A. Press and hold the WARMER (
button then;
B. Press and hold the jETS 1 (
button at the same time for 2 seconds. You will see the temperature
rise to 106°F (41°C) on the LED display. To lower the temperature,
press the COOLER (
C. When the overtemp has been activated, the white decimal point after
the last digit will flash on and off every second as an indicator for
being in the overtemp mode.
Note: Once the temperature goes below 104°F (40°C) and you would
like to raise the temperature to 106°F (41°C) again, you will have to
repeat the steps above.
) button. To lower the set temperature, press
) button. The first press of either button displays the
) button.
)
C
)
1
780 SERIES
1.
2.
3.
A
B
1
2
Figure 1
Page 25