External Dip-Switches - Seagate Scorpion 96 Installation Manual

Dat autoloader
Table of Contents

Advertisement

8

External dip-switches

Figure 3 shows the locations of and default settings for the 10
dip switches on the top of the autoloader. These configuration
options are described in greater detail below.
Figure 3. Location of 10 dip switches on top of internal
autoloader
Block of 10 dip switches
OFF
ON
OFF
ON
SCSI ID: Switches 1, 2, and 3 (the SCSI-ID bit switches) are
used to select the SCSI ID used by the drive, as shown in
Figure 3. You must select a SCSI ID that is not used by any
other devices on the SCSI bus.
S9
S8
S10
Reserved
Self-test
Reserved
(do not use)
Enable
Disable
Note. In some computers the SCSI ID 0 (the autoloader's
default setting) may be used by the bootable hard drive.
DAT Autoloader Installation Manual
Default settings:
S7
S6
S5
Data
compression
Parity
Disable
Enable
Enable
Disable
S4
S3
S2
MRS
SCSI ID Selection
Mode
OFF
OFF
Enable
OFF
OFF
OFF
ON
Disable
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
S1
SCSI ID
0
OFF
ON
1
2
OFF
ON
3
4
OFF
5
ON
6
OFF
7
ON