BEA ULTIMO Manual page 6

Activation and safety sensor for automatic, sliding doors
Table of Contents

Advertisement

1
MOUNTING & WIRING
WIRING
1. Voltage: 12 – 24 VAC, 50/60 Hz; 12 – 30 VDC; < 3.2 W (max)
2. Use either yellow or green, not both.
3. Test monitoring input: low = < 1 V, high = > 10 V (30 V max.); response time: typ. < 5 ms
4. The sensor LED will briefly flash RED and the LCD will display a monitoring notification during monitoring
communication with the door control. This indicates that external monitoring is functional. Sensor
monitoring functionality is automatic by default. Ensure purple wires are properly connected to the door
controller and monitoring is enabled. Sensor monitoring logic is defaulted to ActiveLow. ActiveHigh
monitoring logic is selectable via InTestLogic on menu 3. To turn sensor monitoring OFF, navigate to menu 3
on the LCD and set InTestMode to OFF.
Page 6 of 20
RED
BLACK
BROWN
BLUE
WHITE (COM)
YELLOW (N.C.)
GREEN (N.O.)
PURPLE
PURPLE
POWER SUPPLY
1
POWER SUPPLY
1
SAFETY INPUT
SAFETY INPUT
OPENING INPUT
OPENING INPUT
2
OPENING INPUT
2
TEST OUTPUT
3,4
TEST OUTPUT
3,4
75.0034.03 ULTIMO 20220120