58
Finalizing the Installation
Retirez le couvercle du collecteur et placez-le de côté pour la réinstallation.
3
Suivez les instructions ci-dessous pour remplacer l'orifice.
a
Slide the air shutters to provide access to the orifices.
b
Remove and discard the two gaskets on the front burner orifice.
Manifold
Front Burner Orifice
e
Screw each LP orifice until orifice
protrudes 15/16" (23.8mm)
indicating full insertion (use
wrench to secure manifold when
re-attaching orifice).
© Travis Industries
9/16" Wrench
1/2" Wrench
Rear
Burner
Orifice
1/17/2019 – 1483-FR
(for qualified installers only)
Use a 9/16" wrench to secure the
c
manifold while removing each
orifice with a 1/2" wrench.
Apply thread sealant to the LP orifices
prior to installation. Use the chart below to
identify the correct orifices.
15/16"
Look here for the orifice identification
23.8mm
Front
Rear
d
NG
LP
#49
#56
#49
#57
864 31K CF Install