38
Finalizing the Installation

Exigences de foyer

If installed near carpet or other combustible flooring, the fireplace must be
raised so the base of the unit is above the carpet surface or flooring material.
WARNING:
A non-combustible hearth is not required. However, if the heater is installed next
to the floor, we recommend a hearth to protect the flooring surface from
discoloration or other negative impact from the heater.
© Travis Industries
(for qualified installers only)
1/17/2019 – 1483-FR
A non-combustible hearth may be
installed in front of the fireplace
(entire structure must be non-
combustible). Do not build the
hearth more than 5.625" (143mm)
above the baseplate (this area must
remain open for screen and glass
removal).
864 31K CF Install