6.2 Disassembly
The
disassembly
procedure
disassemble the generator set enclosure and other
parts in order to access the alternator for service. The
procedure provides important information to minimize
disassembly time and indicates where special
configurations exist which may require taking notes.
Remove enclosure
Remove the generator set enclosure as described in the
following steps. See Figure 6-1.
1. Open the enclosure roof.
2. Press the OFF button on the controller and remove
fuse F3 (located in the controller's service access
area). See Figure 4-1.
3. Remove 6 nuts and remove the roof.
Figure 6-2.
1
1. Remove three nuts on each side
Figure 6-2 Roof Removal
88
Section 6 Disassembly/Reassembly
explains
how
to
See
2
1
Right Side
5
1. Roof
2. Rear panel (exhaust end)
3. Left side panel
4. Front panel (air intake end)
5. Right side panel
Figure 6-1 Enclosure
1
3
4
Front (air
intake end)