Kohler 14RES Manual page 119

Residential/commercial generator sets
Hide thumbs Also See for 14RES:
Table of Contents

Advertisement

Group
Parameter
ATS Metering
ATS Contactor Position
Summary
ATS Sources Available
Source 1 Metering
Source 1 Voltage L1-L2
Source 1 Voltage Average Line To
Line
ATS Connection
ATS Source
Configuration
Source 1 System
Source 1 System Voltage
Configuration
Source 1 System Frequency
Source 1 Voltage Debounce Delay
Source 1 Low Voltage Pickup
Source 1 Low Voltage Dropout
Source 1 Calibration
Source 1 Calibration Factor Voltage
L1-L2
Source 2 System
Source 2 Voltage Debounce Delay
Configuration
Source 2 Low Voltage Pickup
Source 2 Low Voltage Dropout
ATS Exercise
Exercise Interval
Exercise Run Duration
Exercise Mode
ATS Delays
ATS Transfer From Preferred Delay
ATS Transfer From Standby Delay
ATS Source 2 Engine Start Delay
Network
DHCP Enabled
Configuration
Static IP Address
(for OnCue)
Static Subnet Mask
Static Default Gateway
Static DNS Server 1
Static DNS Server 2
Server Host Name
Network Status
IP Address
(for OnCue)
Subnet Mask
Default Gateway
DNS Server 1
DNS Server 2
MAC Address
Connected Server IP Address
Network Connection Established
TP-6735 7/17
Adjustment
Range
Access
Units
Read
Read
Read
V
Read
V
Read
Write
V
110--600
Write
Hz
Write
s
0.1--9.9
Write
%
85--100
Write
%
Write
0.65--1.5
Write
s
0.1--9.9
Write
%
85--100
Write
%
Write
Weekly (5)
2 Weeks (6)
Write
min
Write
Unloaded (1)
Economy (2)
Loaded (3)
Write
s
Write
s
Write
s
Write
True/False
Write
Write
Write
Write
Write
Write
Read
Read
Read
Read
Read
Read
Read
Read
Default Setting
240
48--62
60
0.5
90
75--98
90
1.0
0.5
90
75--98
90
Weekly (5)
10--30
20
Unloaded (1)
1--10
3
1--600
120
1--10
3
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
oncue.kohler.com
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0