Kohler 14RES Manual page 58

Residential/commercial generator sets
Hide thumbs Also See for 14RES:
Table of Contents

Advertisement

18. Optional, except for use with OnCuet software as
noted below: Use Kohlerr SiteTecht software to
enter the following generator set information into
the new controller.
Genset Serial Number (from generator set
D
nameplate; required for OnCuet operation)
Engine Serial Number (from engine nameplate)
D
Check the Output Voltage and Frequency
DANGER
Hazardous voltage. Moving parts.
Will cause severe injury or death.
Operate the generator set only when
all guards and electrical enclosures
are in place.
Testing live electrical circuits.
current will cause severe injury or death. Have trained and
qualified personnel take diagnostic measurements of live
circuits. Use adequately rated test equipment with electrically
insulated probes and follow the instructions of the test
equipment manufacturer when performing voltage tests.
Observe the following precautions when performing voltage
tests: (1) Remove all jewelry. (2) Stand on a dry, approved
electrically insulated mat. (3) Do not touch the enclosure or
components inside the enclosure. (4) Be prepared for the
system to operate automatically.
(600 volts and under)
58
Section 4 Controller
Hazardous voltage or
19. Press the RUN button on the controller to start the
generator set. Use a voltmeter to check the output
voltage and frequency. If voltage or frequency
adjustments are required, refer to Section 5.8,
Voltage Adjustment, for instructions.
20. Press the AUTO button to stop the generator set
through normal timing sequences and place the
controller in automatic mode.
Set the Exerciser
21. Set the exerciser. The generator set will exercise
weekly on the same day and time that the exerciser
is started. See Section 4.6 for more information
about unloaded and loaded exercise runs.
a. Press the AUTO button. Check that the AUTO
LED is illuminated.
b. Press the down arrow (RDC) or EXERCISE
(DC) button once to start an unloaded
variable-speed exercise.
starts, EnLd appears on the controller display.
c. If the generator set is connected to a Kohlerr
Model RRT transfer switch: For a loaded
exercise, press the down arrow or EXERCISE
button again. The engine speed increases and
E Ld appears on the controller display.
d. The exercise runs for 20 minutes. Loaded
exercises may run for up to 5 additional
minutes during the engine cooldown cycle.
22. Close the roof and lock the enclosure.
After the engine
TP-6735 7/17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

14resl20res20resl

Table of Contents