Credentials hard coded into the WIFI Module/Network Interface Card (NIC). The Site must add LFwireless SSID to their
network.
Required Action of the Installer: Verify that the facility has successfully added the LFwireless SSID to their network. To
do this, verify that the 'WIFI Not Connected' indicator on LCD screen is not visible.
If the facility has not added this SSID to their network, installer should reach out to the account manager/sales
representative responsible for this customer to coordinate with the customer's network administrator.
SMARTsync Registration
Use the QR code reader to register the SMARTsync via the QR code found on the SMARTsync.

Machine Verification

As long as the SMARTsync is connected to the same network switch as the WASPs, there should be no distance
constraint for setting up the SMARTsync relative to the WASPs.
1. Click 'Verify' on the LF Assist home screen after steps 1-5 are completed.
2. Select the machine to verify by clicking Verify' next to that machine's name.
3. Select the appropriate unit of measure (Imperial or Metric)
4. Scan the QR code on the LCD of the machine using the QR code reader built into the application
5. Complete the required number of reps at the weight setting indicated.
6. Click 'Done' when repetitions completed.
7. If the machine is verified successfully, click 'End Verification'.
8. If the machine is not verified successfully, click 'Calibrate' and begin calibrating.

Machine Calibration

Complete the machine calibration process for those new SMARTconnect units that are not properly verified, or any
retrofit units installed in the facility.
1. Select the machine to be calibrated (either using 'Calibration' tile on home screen, or directly from Machine
Verification in step 6.
2. Select proper unit of measure on Calibration setup screen and adjust the max weight setting if required.
3. Press 'Begin Calibration'.
4. Mount the WASPs over and around the strength area to ensure full coverage of data connectivity.
a. Using an appropriate tool (i.e. cell-phone SIM release tool, paperclip), gently press the 'Config Enable' button
located on the downward (weight stack facing) face of the Guide Rod Retainer/SMARTconnect Sensor Housing.
You should get a slight confirming feel when the button is pressed properly.
b. While holding the 'Config Enable' button down, use a similar too to press-then-release the 'System Reset'
button located on the downward (weight stack facing) face of the Guide Rod Retainer/SMARTconnect Sensor
Housing. Continue to hold the 'Config Enable' button for two seconds after releasing the 'System Reset'
button, then release the 'Config Enable' button.
c. The LCD should display three numbers arranged vertically in the upper are of the LCD, and three letters, or
numbers, in the bottom region of the LCD. They should disappear after several seconds.
d. The system is now in 'Config Mode' and will accept configuration data over the Bluetooth connection.
5. When the machine has been placed in 'Config Mode', user will be able to automatically redirected to the next
screen.
6. Adjust the pre-set weight to the closest weight setting if pre-set weight is not available.
7. Check the 'Field Calibration Tool In Use' box if the field calibration tool is used at this weight setting.
8. Press 'Begin Step'.
9. Lift and hold the weight until the application indicates 'Done'.
10. Repeat steps 6-10 above for the six calibration weights as determined by the application.
11. Press 'Save'.