ER-GC33/ER-GC30 1 Warning Caution: • Pb free solder has a higher melting point that standard solder; Typically the melting point is 50 - 70°F (30 - 40°) higher. Please use a soldering iron with temperature control and adjust it to 750 ± 20°F (400 ± 10°). In case of using high temperature soldering iron, please be careful not to heat too long.
ER-GC33/ER-GC30 3 Troubleshooting Guide (Refer to Wiring Connection Diagram)
Page 4
ER-GC33/ER-GC30 4 Disassembly and Assembly Instructions 4.1. Disassembly Instructions 1. Take out blade. 2. Loosen two screws at right and left side of springs and two screws on housing B. 3. To separate housing A and B with care for preventing breakage of hooks.
Page 5
ER-GC33/ER-GC30 4.2. Assembly Instructions 1. Assemble module block and motor into housing A. Make sure of a position to be set “○” with both switch handle and switch contact at the rear side of module. 2. Confirm module block or motor to be set into housing A firmly, and then check its operation with connecting adaptor.