To Replace Regulator - Porter-Cable N003568 Instruction Manual

Oil-free pump
Table of Contents

Advertisement

Available languages

Available languages

6.
Apply sealant to the check valve threads. Reinstall the check valve (turn clock-
wise).
7.
Replace hose and new hose clamp.
Perform the Break-in Procedure. See Break-in Procedure in the Operation
8.
section.

TO REPLACE REGULATOR

Release all air pressure from air tank. See To Drain Tank in the Maintenance
1.
section.
2.
Unplug unit.
3.
Remove the console cover.
4.
Using an adjustable wrench remove the gauges, quick connect, and safety
valve from the regulator manifold.
Console Cover
Remove the hose by removing the hose clamp. NOTE: The hose clamp is not
5.
reusable. You must purchase a new hose clamp, see Replacement Parts in
the Service section or purchase a standard hose clamp at a local hardware
store.
6.
Remove pump mounting screws securing pump (one on each side).
7.
Carefully slide pump from brackets
and out of the way.
8.
Using an adjustable wrench remove
the regulator manifold.
9.
Apply pipe sealant to new regulator
manifold and assemble, tighten with
wrench.
10. Reapply pipe sealant to gauges,
quick connect, and safety valve.
11. Reassemble all components in reverse order of removal. Make sure to orient
gauges to read correctly and use wrenches to tighten all components.
N003568
Safety
Valve
Hose
Clamp
14 - ENG
Gauges
Regulator Manifold
Pump Mounting Screw
Quick
Connect
Pump
shown
moved
out of the
way
Regulator
Manifold

Advertisement

Table of Contents
loading

This manual is also suitable for:

C2002

Table of Contents