Status indicators
The table below provides an overview of the LED status displays of the charging points:
SICHARGE Operating Manual ERK
Operating Manual, 02/2022, A5E48572458-AD
Does not light up
If the status indicator does not light up, this indicates an
interruption to the power supply. If there is not a power
failure, check the backup fuses.
Lights up white
The controller is deactivated. The charging point is not avail-
able.
Flashing white
Controller has been started. The charging point is not availa-
ble at the moment.
Lights up green
Charging of vehicles is possible.
Flashes green
No cable plugged in. Charging point is signing charging
process.
Lights up yellow
The charging point is connected to the vehicle.
No charging in progress.
Flashes yellow
A cable is plugged in. No authorization for charging, because
charging station is still in the signing process.
Pulsating blue light
Charging process active:
The connected vehicle is receiving power.
Lights up blue
Charging inactive:
The connected vehicle is not drawing any power.
Flashing blue
Meter data for the charging process are being signed.
Flashes red 1x
Flashes red 2x
Main contactor
Flashes red 3x
Circuit breaker (CB) has tripped
Flashes red 4x
The residual current circuit breaker (RCCB) has tripped
Flashes red 5x
Connector lock error
Flashes red 6x
Meter error
Flashes red 7x
Vehicle error: Mode 3 unknown status
Flashes red 10x
SD card error
EVSE connection error
EV connection error