3Com 3C996B-T User Manual page 70

Gigabit server network interface cards
Table of Contents

Advertisement

6
Novell NetWare Driver Setup
62
NOTE: Bind B57_1_EII to BASP_1_E82 is also bound to BASP_1_E82. VLSOT
range is from 1 to 4 (only four TEAMS can be configured.)
Example of VLAN with Advanced Server Features:
LOAD BASP.LAN FRAME=ETHERNET_II NAME=BASP_1_V100_EII VSLOT=1
VLAN=100
LOAD BASP.LAN FRAME=ETHERNET_II NAME=BASP_1_V100_EII VSLOT=1
VLAN=200
LOAD BASP.LAN FRAME=ETHERNET_II NAME=BASP_1_V100_EII VSLOT=1
VLAN=300
LOAD B57.LAN FRAME=ETHERNET_II NAME=B57_1_EII SLOT=1
LOAD B57.LAN FRAME=ETHERNET_II NAME=B57_1_EII SLOT=2
BASP BIND BASP_1_V100_EII B57_1_EII
BASP BIND BASP_1_V100_EII B57_1_EII
BIND IP BASP_1_V100_EII ADDR=172.16.210.1 MASK=255.255.0.0
BIND IP BASP_1_V200_EII ADDR=172.17.220.1 MASK=255.255.0.0
BIND IP BASP_1_V200_EII ADDR=172.18.230.1 MASK=255.255.0.0
NOTE: Bind B57_1_V100_EII, B57_1_EII are also bound to the other
VLANs on the same VSLOT. VLAN refer to VLAN ID and valid VLAN ID ranges
from 1 to 4096.
Example of TRUNKING with BASP:
LOAD BASP.LAN FRAME=ETHERNET_II NAME=BASP_1_EII VSLOT=1
MODE=TRUNK
LOAD B57.LAN FRAME=ETHERNET_II NAME=B57_1_EII SLOT=1
LOAD B57.LAN FRAME=ETHERNET_II NAME=B57_1_EII SLOT=2
BASP BIND BASP_1_EII B57_1_EII
BASP BIND BASP_1_EII B57_2_EII
BIND IP BASP_1_EII ADDR=172.16.210.1 MASK=255.255.0.0
NOTE: Switch ports must configure for Trunking (FEC or GEC-Cisco only).
Example of GVRP with BASP:
LOAD BASP.LAN FRAME=ETHERNET_II NAME=BASP_1_EII VSLOT=1
MODE=GVRP
LOAD B57.LAN FRAME=ETHERNET_II NAME=B57_1_EII SLOT=1
LOAD B57.LAN FRAME=ETHERNET_II NAME=B57_1_EII SLOT=2
BASP BIND BASP_1_EII B57_1_EII
BASP BIND BASP_1_EII B57_2_EII
BIND IP BASP_1_EII ADDR=172.16.210.1 MASK=255.255.0.0
NOTE: Switch ports must configure for GVRP.