Connection With The Pc; Time Adjustment With An External Equipment - Panasonic WJ-SX 150A Operating Instructions Manual

Panasonic matrix switcher wj-sx150a operating instructions
Table of Contents

Advertisement

Connection with the PC

1. Conform the communication speed (SERIAL PORT
SPEED) parameter in SETUP MENU to that of the PC.
2. Connect the matrix switcher's serial port to that of the
PC with the 9-pin D-sub cable.
D-sub9
D-sub25
Personal Computer
Notes:
• The following parameters are fixed.
Data bit: 8 bits
Parity check: none
Stop bit: 1 bit
• Refer to Cable Specifications in this page for details on
cables.
Cable Specifications
PC
1
2
3
4
5
6
7
8
Frame
48
or
D-sub9
SERIAL
Matrix Switcher
Matrix Switcher
1
2
3
4
5
6
7
8
Frame
Shield
Time Adjustment with an External
Equipment
The specified external devices can output the time adjust-
ing signal to the matrix switcher.
This signal can adjust the time by up to ± 30 seconds every
hour.
To use this function, it is necessary to assign the alarm
input terminal(s) (pin # 1 to 16) to the time adjusting termi-
nal(s).
SETUP MENU or WJ-SX150A Administrator Console can
assign the signal.
Note: In the master-slave connection, time setting of every
unit can be synchronized when the time adjusting sig-
nal is input to any unit.
Master Clock Connection Example
for Time Adjustment
Connect the matrix switcher's time adjusting terminal to
those of the master clock with the twisted pair cable.
The figure below shows the case in which Alarm Input 16 is
assigned as the time adjusting terminal.
Note: A master clock with N.O. (Normally Open alarm con-
tact)-type output is connectable.
Matrix Switcher
ALARM
Pin #22
Pin #21
GND
12
9
3
6
Master clock