The switch on a daisy-
chain-connected unit
other than the
extremities must be set
to OFF.
(A)
OFF
(B)
GND
DATA HDR
DATA 4
DATA 3 DATA 2
TERM
OFF
ON
PS•DATA
Auto termination works inside the matrix switcher.
Unit address 4
Unit address 3
Set the same
number for the
camera's unit
address as and
CAMERA IN.
DATA 3 DATA 2
RS485(CAMERA)
16
10
9
IN
OUT
16
10
9
CAMERA
38
The switch on the end
unit should be set to
ON.
(A)
ON
OFF
ON
(B)
GND
WV-CPR450 and others
(For the termination
switch positions, refer
to the operating
instruction of the
corresponding unit.)
RS485(CAMERA)
DATA 1
LINE
SELECT
2
4
RS485(CAMERA)
Matrix Switcher
Unit address 2
Unit address 1
DATA 1
8
7
6
5
4
3
8
7
6
5
4
3
Matrix Switcher

Connection with the Monitors

Connect the monitors to the MONITOR OUT connectors at
the unit's rear panel with the coaxial cable.
The connectors MONITOR OUT 1 to 4 are associated to
Monitor 1 to 4. When you control the monitors from a PS·
Data controller, the connectors MONITOR OUT are associ-
ated to Unit 1 to 4.
Set it to 2 or 4
(the same as
the connected
equipment).
Monitor 3
2
1
2
1
Martix Switcher
3
1
4
2
MONITOR OUT
Monitor 4
Monitor 2
Monitor 1