Pioneer PDP-R04G Service Manual page 169

Table of Contents

Advertisement

1
2 FUNCTION CHECK
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
A
1
F U N C T
2
3
4
5
6
7
8
9
10
11
12
13
14
F A N
< = >
15
16
B
No.
Display
1
IC1 TEST
2
IC2 TEST
3
IC3 TEST
4
IC4 TEST
5
FAN <=>
6
AFT <=>
7
BSD ANT VOLT <=>
8
AUTO PRESET CHECK <=>
C
2.1 FAN
Controls FAN speed by force. (MIN : STOP, CNT : Low Speed, MAX : High)
Temp sensor is working only displaying data value in service factory mode.
After getting off service factory mode, this function is set to normal automatically.
2.2 AFT LOCK
For production line use only
Stop AFT tuner received function and receive a center frequency.
D
After turning off a unit (including stand-by mode), this setting is set normal (AFT function) automatically.
It's performed to two tuner and DTV tuner to U.S. model.
2.3 AUTO PRESET CHECK
For production line use only
Select No.
Display
1 (Default)
NO
7
YES
E
F
118
1
2
I O N
C H E C
K
V D 1 – 1 3 1 – N T V – J H S
: M I N
Detail
: MINI ⇔ CONT ⇔ MAX
UNLOCKED ⇔ LOCKED
15V ⇔ 11V ⇔ 0
NO ⇔ YES
Function
Perform AUTO PRESET function to specific frequency
to reduce AUTO RESET time at production line.
2
3
No last memory in this menu
Remarks
For CMX
For CMX
For CMX
For CMX
For Factory use
Only domestic model
Only Europe HD and for
Factory use
Performing this function when shifting from
"NO" to "YES".
PDP-R04E
3
4
232C Command
*1
ALN/ALY
BVH/BVM/BVL
None
Remarks
4