Trane MWW509IB Installation Manual page 17

Table of Contents

Advertisement

Indoor Unit Installation
Install the mounting plate
Adjust the horizontal level of the
1.
mounting plate.
Fixing the mounting plate on the wall
2.
with screws.
Pull the mounting plate manually to
3.
check its reliability after installation.
Be sure that the mounting plate has
been fixed firmly enough to with
stand the weight of an adult of
60kg, furthermore, the weight
should be evenly shared by each
screw.
Cut the piping hole
1.
Make the piping hole ( 65) in the
wall at a slight downward slant to
the outdoor side. The center of the
hole should be determined refer to
Figure 1.
2.
Insert the piping-hole sleeve into the
hole to prevent the connection pip-
ing and wiring from being damaged
when passing through the wall.
Install the drain hose
1.
For well draining, the drain hose
should be placed at a downward
slant.
2.
Do not wrench or bend the drain
hose or flood its end by water (Fig-
ure 2).
3.
Lengthened drain hose should be
wrapped with insulation when
going through the room.
Install the connection tube
Connect the the connection tubes, and
fasten the coupling nuts of the connec-
tion tubes. (See "Install the connection
tube"section).
MCW - SVN13A - E4
Installation for
CAUTION!
Connect the connection tube with
the indoor unit firstly, and that the
outdoor unit.
Be careful in bending the
connection tube, or you will damage
the tube.
If the tightening torque is too big in
tightening the flare nuts, leakage will
happen.
Figure 1
Figure 2
MWW530IB/TWK530JB
Electrical Wiring
1.
Open the front cover upwards.
2.
Remove the wiring cover as shown
in figure 3.
3.
Put the power connecting cables
through the chassis and control box
bottom from down to up.
4.
Connect the blue power supply cable
with the terminal "N(1)"on the termi-
nal block, the brown one with termi-
nal "2", the red one with terminal "3",
and the yellow-green one (earth wire)
with the terminal "
5.
For heat pump model, one control cord
should be connected through connec-
tor and should be clamped with a
clamp.
6.
Install the wiring access cover to the
original place and fasten the screws.
7.
Put back the front cover.
",(Figure 3)
17

Advertisement

Table of Contents
loading

Table of Contents