Outdoor Unit Installation
Install the connection tube
1. Align the center of the piping flare with
the relevant valve valve.
2. Screw in the flare nut by hand and then
tighten the nut with spanner and torque
wrench (figure 6). Tightening torque is
listed in the following table.
Figure 6
16
Installation for
Hex nut diameter
Tightening torque
(mm)
6
9.5
12
16
MWW526IB/TWK526JB
Electric wire Connection
1. Remove the front right side panel of
the outdoor unit and knock through the
outdoor wire hole. Put on the wiring
rubber ring.
(N m)
2. Remove the wire clamp and connect the
end of the power connection cord with
15 ~ 20
screws to the wiring terminal board as
shown in figure 7.
31 ~ 35
3. Fix the power connecting wire and control
50 ~ 55
cord by using the wire clamp.
4. Make sure that the wiring has been con-
60 ~ 65
nected securely.
5. Install the front side panel.
Figure 7