Indicators Audible - Metrologic VoyagerGS MS9590 Installation And User Manual

Metrologic instruments single-line hand held laser scanner installation and user's guide ms9590
Hide thumbs Also See for VoyagerGS MS9590:
Table of Contents

Advertisement

I
NDICATORS
Audible
During operation, the MS9590 provides audible feedback that indicates the
status of the scanner and latest scan. Eight settings are available for the tone of
the beep (normal, 6 alternate tones and no tone). To change the beeper tone,
refer to the MetroSelect Single-Line Configuration Guide or MetroSet2's help
files.
One Beep
When the scanner first receives power, the blue LED will turn on, the white
LED will flash, and the scanner will beep once. The scanner is ready to scan.
When the scanner successfully reads a bar code, the white LED will flash and
the scanner will beep once.
Three Beeps
During Operation
When entering the configuration mode, the white LED will flash while the
scanner simultaneously beeps three times.
When exiting the configuration mode, the scanner will beep three times and
the white LED will stop blinking.
Three beeps can also indicate a communication timeout during normal
scanning mode if the scanner is configured to give this indication.
During Start-up
This is a failure indicator. Refer to "Failure Modes" on page 18.
Three Beeps
When using the single-code-configuration method, the scanner will sound a
3-combination tone (a single beep then a short pause followed by, a high tone,
and a low tone). This beep sequence signals that the single configuration bar
code has successfully configured the scanner.
Razzberry Tone
This tone indicates a type of failure. Refer to "Failure Modes" on page 18.
When in configuration mode, a short razzberry tone will sound if an invalid bar
code is scanned.