Mechanical; Electrical; Environmental - Metrologic VoyagerGS MS9590 Installation And User Manual

Metrologic instruments single-line hand held laser scanner installation and user's guide ms9590
Hide thumbs Also See for VoyagerGS MS9590:
Table of Contents

Advertisement

D
S
ESIGN
PECIFICATIONS
M
ECHANICAL
Height H
Width W
Depth:
Weight:
E
LECTRICAL
Input Voltage:
Power:
Current:
DC Transformers:
For regulatory compliance information see pages 33 – 35.
E
NVIRONMENTAL
Temperature:
Humidity:
Light Levels:
Shock:
Contaminants:
Specifications are subject to change without notice.
28
1
:
160 mm (6.30")
2
H
:
41 mm (1.60")
1
:
65 mm (2.56")
2
W
:
25.4 mm (1.00")
100 mm (3.93")
150g
5VDC ± 0.25V
Operating = 650 mW typical
Standby = 375 mW typical
Operating = 130 mA @ 5VDC typical
Standby = 75 mA @ 5VDC typical
Class 2; 5.2V @ 1A
Operating = 0°C to 40°C (32°F to 104°F)
Storage = -40°C to 60°C (-40°F to 140°F)
5% to 95% relative humidity, non-condensing
Up to 4842 Lux (450 footcandles)
Designed to withstand 1.5 m (5 ft.) drops
Sealed to resist airborne particulate contaminants
MS9590 Series Specifications