[Unable To Fill Wiper Cleaning Liquid]; [Pinch Roller Error]; [Print Head Height Mismatch]; [Insufficient Media Width] - Roland TrueVIS SG3-540 User Manual

Hide thumbs Also See for TrueVIS SG3-540:
Table of Contents

Advertisement

・ P. 134 How to Cut with Crop Marks
・ P. 194 Correcting the Reading Sensor

[Unable to Fill Wiper Cleaning Liquid]

The cleaning liquid pouch ran out while supplying this liquid for cleaning or to the wiper tray.
Quickly replace this cleaning liquid pouch with a new one.

[Pinch Roller Error]

The left (right) pinch roller is positioned at a location where it cannot pinch the media.
Raise the loading lever and move the pinch roller to the correct location.
RELATED LINKS
・ P. 30 Setup of New Media
・ P. 67 Setup of Registered Media

[Print Head Height Mismatch]

The set print head height and the actual print head height are different.
Follow the instructions on the screen to change the print head height. When you change this height, [OK]
is displayed on the screen. Tap [OK] to resume printing.
If 10 minutes elapse after the print head carriage moves, this carriage is capped and the data is canceled
to prevent the heads from drying out.
RELATED LINKS
・ P. 153 Changing the Print Head Height

[Insufficient Media Width]

[The print data is larger than the media width. Continue output?]
This message appears when the size of the printing data is larger than the printing area of the loaded
media.
To continue performing output without making corrections, tap [Continue Output]. At this time, the por-
tion extending beyond the printing area is not output.
To cancel output, tap [Cancel]. Make the printing area wider, for example, by replacing the media with a
larger piece of media, and then send the data again.
MEMO
There is no limitation on the size of the data in the media-feed (FEED) direction.
[Crop marks cannot be added because the print data is larger than the media width. Continue output?]
This message appears when one of the following situations is detected.
• The size of the data with crop marks is larger than the printing area of the loaded media.
• The width of the printing data is 60 mm (2.36 in.) or less.
Error Messages