Connecting A Local Maintenance Terminal - ADC Soneplex HMS-358 Installation And Verification Manual

Hide thumbs Also See for Soneplex HMS-358:
Table of Contents

Advertisement

LTPH-SM-1014-03, Issue 3
C
ONNECTING A
Maintenance terminal
Serial COM port
Interface cable
Figure 20. Connecting a Maintenance Terminal to the HMU Craft Port
Step
Procedure
The HMU DCE should be connected to the DTE port of the local maintenance terminal. If
the connection to the HMU requires a DTE-to-DTE or DCE-to-DCE interface, see the HMU
technical practice for more information.
1
Connect a standard 9-pin, terminal cable to the HMU front panel craft (DB-9) port or connect a 25-pin
terminal cable to the OSS port on the shelf backplane.
The craft port is configured as DCE. The OSS port is configured as DTE.
2
Connect the other end of the terminal cable to the serial COM port on the maintenance terminal.
3
Start a VT100 terminal emulation program, such as HyperTerminal or Procomm, on the PC.
4
Configure the maintenance terminal as follows:
• 9600 baud
• No parity
• 8 data bits
• 1 stop bit
5
Proceed to
"Using the Terminal Access Option" on page
? ? ? ?
Installer Signature
HMS-358 List 1 and List 2
L
M
OCAL
AINTENANCE
January 12, 2001
T
ERMINAL
HMU Craft port
32.
Installing a Management Unit (HMU)
Installer Check ü ü ü ü
H
H
H
H
H
Date
31