Kenwood HM-582MD Instruction Manual page 36

Kenwood stereo system user manual
Hide thumbs Also See for HM-582MD:
Table of Contents

Advertisement

Contents
36
Sampling frequency
Three types of digital signals are usually used according to the sampling frequencies. The sampling frequencies
vary depending on the types of digital equipment as shown below.
32 kHz
: Standard and long-hour modes of DAT, etc.
44.1 kHz
: Standard mode of DAT, CD, MD, etc.
48 kHz
: Standard mode of DAT, etc.
(DAT : Digital Audio Tape deck)
In general, high-quality recording based on digital signal transmission is not possible unless the source and
recorder components use the same sampling frequency. As this unit has a built-in sampling rate converter, digital
signals with 32 kHz and 48 kHz can be recorded by conversion to the MD sampling frequency (44.1 kHz).
Digital recording and SCMS
Designed for copyright protection, the SCMS is a
prescription that copying of digital signals as they
are in the digital form between digital audio equip-
ment is allowable only for one generation.
Digital recording is not available with commercially
marketed music software (CD, MD, etc.) containing
the copy prohibit code.
In regard to display messages
Recording is not possible when one of the following messages is displayed.
Recording is not possible if the following characters
are displayed.
"DISC FULL"
: Disc is full
\ Erase undesired tracks.
"PROTECTED" : The accidental erasure protect tab is
open.
\ Close it.
"PLAY ONLY"
: A playback-only Mini Disc is loaded.
\ Load a recordable Mini Disc.
"Please Wait"
: An attempt is made to record a CD in
less than 74 minutes after high-speed
recording of the same CD was started
before.
\ Start high-speed recording after
YIO
the displayed time has elapsed or
record the CD with normal-speed
recording.
Copy using
digital input
Copy using
analog input
Copy using
analog input
Digital recording is not possible if the following
characters are displayed.
"UNLOCK"
k
"SCMS"
"NOT AUDIO" : The input digital signal is not an
Recording on MD
Digital copy
Copy using
cannot be
digital input
repeated.
Copy using
analog input
Copy using
digital input
Copy using
digital input
: The sampling frequency is not 32
kHz, 44.1 kHz, 48kHz.
\ Use analog recording.
: The optical fiber cable is un-
plugged or loosened. (The con-
nector is not connected.)
\ Connect the optical fiber cable
correctly.
: Digital recording is prohibited by
SCMS.
\ Use analog recording.
audio signal.
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hm-582

Table of Contents