Settings sheet

Setting
Description
Preliminary settings
20
language
1
hour / minutes
2
day / month
3
year
5700
installation confi g.
Heating circuit No. 1
if 2 circuits = the least warm one (e.g.: fl oor)
710
comfort setpoint
712
reduced setpoint
720
heating curve slope
741
fl ow temp setpoint max
750
room infl uence
790 / 791
optimis. at switch-on / off
834
servomotor travel time
850 / 851
fl oor drying
Heating circuit No. 2 (with 2
= the warmest one (e.g.: radiators)
1010
comfort setpoint
1012
reduced setpoint
1020
heating curve slope
1041
fl ow temp setpoint max
1050
room infl uence
1090 / 1091
optimis. at switch-on / off
1134
servomotor travel time
1150 / 1151
fl oor drying
Domestic Hot Water
1610
nominal DHW temp. setpoint
1612
reduced DWH temp. setpoint
1620
DHW release
1640 to 1642 legionella cycle
5024
DHW switch-on differ.
5030
charging time limitation
5061
heater release
- 82 -
Set to.
Menus
operator
section
time & date
time & date
time & date
confi guration
HC1 adjust.
HC1 adjust.
HC1 adjust.
HC1 adjust.
HC1 adjust.
HC1 adjust.
HC1 adjust.
HC1 adjust.
nd
circuit option)
HC2 adjust.
HC2 adjust.
HC2 adjust.
HC2 adjust.
HC2 adjust.
HC2 adjust.
HC2 adjust.
HC2 adjust.
DHW
DHW
DHW
DHW
DHW tank
DHW tank
DHW tank
Setting
Description
Boiler backup (with "Boiler" kit option)
3700
OT.switch-on authoris.
3705
swith-off delay
Miscellaneous
6420
input H33 function
6100
OT sensor correction
6120
frost protection on/off
6205
reset settings
6220
software version
6711
reset heat pump
Cooling (with "Cooling" kit option)
5711
cooling unit
Faults (if a fault occurs, press"Info" key)
No. 10
outdoor sensor
No. 33
fl ow temp. sensor
No. 44
return temp. sensor
No. 50
DHW temp. sensor
No. 60
room sensor 1
No. 65
room sensor 2
No. 105
maintenance message
No. 121
HC1 fl ow T not reached
No. 122
HC2 fl ow T not reached
No. 127
leg. prot. T not reached
No. 369
external fault (EX3)
No. 370
outdoor unit connect error
6711
reset heat pump
Heat pump
2844
switch-off temp max
2884
OT auth. to start elec. aux.
2920
Pk day clear (EX1) rel / lock
Swimming pool (with "swimming pool" kit option)
2056
generator setpoint
Outdoor unit faults (see
Waterstage Split Comfort DHW Serie / INSTALLATION / 2125 - EN
Set to.
addit. gen.
addit. gen.
1
confi guration
confi guration
confi guration
confi guration
confi guration
2 pipes
confi guration
heat pump
heat pump
heat pump
page
66)
Menus
error
error
Sw pool