Fujitsu Waterstage Split Comfort 5 Series Installation Manual page 56

Air/water heat pump split 2 services
Table of Contents

Advertisement

Line
Function
Heat pump (HP)
2779
I
Pump speed max condenser pump cooling mode
2793
I
Pump speed max condenser pump
2803
S
Overrun time cond pump
2843
S
Compressor off time min
2844
S
Switch-off temp max
2862
S
Locking time stage 2 / mod
2873
S
Compressor mod run time
2882
S
Release integr electric fl ow
2884
S
Release el fl ow below OT
Electrical release - start-up with outdoor
temperature
2886
S
Compensation heat defi cit
2907
S
Silent mode power max
2916
S
Max setpoint HP DHW charg
2920
S
With electrical utility lock (EX1)
(fi g. 45, page
Released : HP = ON _ Back-up DHW = off _ 1
Locked (Blocked on standby) : HP = off _ Back-up DHW = off _ 1
Boiler = ON
3026
S
Silent mode on
3027
S
Silent mode off
3028
S
Silent mode speed incr start
3029
S
Silent mode speed incr end
Energy meter
3095 --> 3110 : Not used
3113
U
Energy brought in
Cumulation of total consumed electrical energy.
Electrical energy consumed = Electrical energy absorbed by outdoor unit + electric energy absorbed by the heating
electrical backup and / or DHW electrical backup (if installed).
3121 --> 3123 : Not used
3124
U
Energy brought in heating 1 (N - 1)
3125
U
Energy brought in DHW 1
3126
U
Energy brought in cooling 1
3128 --> 3130 : Not used
3131
U
Energy brought in heating 2 (N - 2)
3132
U
Energy brought in DHW 2
3133
U
Energy brought in cooling 2
3135 --> 3137 : Not used
3138
U
Energy brought in heating 3 (N - 3)
3139
U
Energy brought in DHW 3
3140
U
Energy brought in cooling 3
3142 --> 3144 : Not used
Note: "Energy" Counters increment as of 1 July each year.
- 56 -
39)
Setting range
or display
70... 100 %
70... 100 %
8... 600 s
0... 120 min
8... 100 °C
0... 40 min
10... 600 s
0... 500 °Cmin
-30... 30 °C
Off , On,
Only with fl oor curing fct
--, 1... 100 %
8... 80 °C
Locked (Blocked on standby),
Released
st
back-up HP = off _ 2
nd
back-up HP = off _ Boiler = ON
back-up HP = off _ 2
st
00:00... --:--
00:00... --:--
-50... 50 °C
-50... 50 °C
Waterstage Split Comfort DHW Serie / INSTALLATION / 2125 - EN
Setting
Basic
increment
setting
1 %
100 %
1 %
100 %
1 s
240s
1 min
8 min
1 °C
75 °C
1 min
5 min
1 s
240 s
1 °Cmin
100 °Cmin
2 °C
Off
1 %
--
1 °C
--
Released
back-up HP = off _
nd
10 min
22:00
10 min
07:00
1 °C
8 °C
1 °C
7 °C
Kwh
--
Kwh
--
Kwh
--
Kwh
--
Kwh
--
Kwh
--
Kwh
--
Kwh
--
Kwh
--
Kwh
--