Auxiliary Alarm Signalling Equipment - ADEMCO VISTA-100 Installation Instructions Manual

Commercial fire and burglary partitioned security system with scheduling
Hide thumbs Also See for VISTA-100:
Table of Contents

Advertisement

Auxiliary Alarm Signaling Equipment
4142TR
CABLE
4142TR
CABLE
WIRE
COLORS
– 74 –
www.PDF-Zoo.com
The J2 connector can be used to provide triggers for the following conditions:
• Fire alarm
• Burglary/audible panic alarm
• Silent panic/duress alarm
• Fire supervisory
• Trouble
• Opening/closing (arming/disarming)
These triggers may be used to trip auxiliary alarm signaling equipment such as
Ademco's 7720, 7720ULF, and 7920SE Long Range Radios. Note that not all of
these triggers are available for all settings of field 3*20. Consult the J2 PIN
ASSIGNMENTS AND FUNCTIONS diagram shown earlier for configuration of
the J2 triggers..
The open/close, fire alarm, fire supervisory, burglary/audible panic alarm, silent
panic/duress alarm, and trouble triggers are common to all partitions and must be
enabled for each partition (data field 2*20). The open/close trigger is LOW when
all enabled partitions are armed, and HIGH when any enabled partition is
disarmed. The remaining triggers are normally LOW and go HIGH when the
corresponding condition occurs in at least one enabled partition. The fire and
burglary/audible panic alarm triggers remain HIGH until a [User Code] + OFF is
entered in all enabled partition(s) which display these conditions. The silent
panic/duress trigger works the same way, except that it is momentary when
initiated by duress. The fire supervisory and trouble triggers remain HIGH until
the underlying faults are corrected and the [User Code] + OFF is entered in all
enabled partition(s) which display these conditions.
Figures 19a, b, and c show how to make connections to the 7720, 7720ULF, and
7920SE Long Range Radios.
7720 WIRING DIAGRAM
J2 CONNECTOR
1
2
3
4
5
6
7
8
NOTES:
• MOUNT THE 7720 WITHIN 3 FEET OF THE C-COM. RUN WIRING FROM C-COM TO 7720 IN CONDUIT.
Figure 19a: Connections to 7720 Long Range Radio
firealarmresources.com
9
7720 RADIO
(USE 7720 ULF INSTEAD
FOR COMMERCIAL FIRE
INSTALLATIONS)
1
RADIO FAULT (PROGRAM FOR SHORT ON FAULT)
GROUND
FIRE ALARM
BURG/AUDIBLE PANIC ALARM
TROUBLE (ZONE TROUBLE, TELCO FAULT, ETC.)
SILENT PANIC/DURESS ALARM
SEE 7720 INSTRUCTIONS FOR
MORE DETAILED INSTALLATION
INFORMATION
FAULT
2
3
4
5
6
7
8
9
10
11