OBSERVATION POSSIBLE CAUSE
Wash
1. Water level low.
temperature not
within range.
2. RTD setpoint too low.
3. Defective RTD.
4. Wash heater defective.
5. Defective heater contactor.
Rinse
1. RTD is defective.
temperature not
2. Incoming rinse water does not
within range.
meet minimum temperature on
i
machine data plate.
3. Rinse heater damaged.
4. Setpoint screens set low.
5. Defective heater contactor.
Machine
1. Drain clogged.
doesn't drain
when power
2. Defective drain valve.
button is
pressed.
3. Defective wash pump.
4. Defective motor contactor.
5. Defective timer.
Incorrect water
1. Water turned off.
pressure
displayed
2. Transducer disconnected.
during Fill or
Rinse.
3. Pressure transducer defective.
07610-004-99-71-B
TROUBLESHOOTING
REMEDY
1. Check water level. If low, run new fill cycle.
2. Adjust setpoint.
3. Replace RTD.
4. Replace heater element.
5. Replace contactor.
1. Replace if necessary.
2. Adjust as required.
3. Check amperage. Replace if necessary.
4. Adjust rinse tank setpoint.
5. Replace contactor.
1. Remove obstruction.
2. Replace drain valve.
3. Replace wash pump.
4. Replace contactor.
5. Replace timer.
1. Turn water on.
2. Verify wiring.
3. Replace pressure transducer.