Inverter Specification; Inverter Specification 1.2.1 Sj300 - Hitachi L300P Series Service Manual

Hitachi inverter service manual
Hide thumbs Also See for L300P Series:
Table of Contents

Advertisement

1.2 Inverter specification

1.2.1 SJ300
Monitor Mode
Dis-
Function name
play
code
Output frequency
d001
monitor
Output current
d002
monitor
Operation direction
d003
monitor
PID feedback
d004
monitor
Intelligent input
d005
terminal monitor
Intelligent output
d006
terminal monitor
Frequency
d007
conversion monitor
d012
torque monitor
Output voltage
d013
monitor
Input electric power
d014
monitor
Accumulated time
d016
monitor during
RUN
Power ON time
d017
monitor
Number of trip time
d080
monitor
d081
Trip monitor 1
d082
Trip monitor 2
d083
Trip monitor 3
d084
Trip monitor 4
d085
Trip monitor 5
d086
Trip monitor 6
d090
Warning monitor
Output
frequency
F001
setting
st
F002
1
acceleration time
F202
nd
acceleration time
2
rd
F302
acceleration time
3
F003
st
deceleration time
1
F203
nd
deceleration time
2
rd
F303
deceleration time
3
Operation direction
F004
selection
(Note1) Change mode during run by selection of b031 (software lock selection).
(Note2) Do not forget to press "STR" key when you change the display.
SJ300 monitor or data range
(digital operator)
0.00-99.99/100.0-400.0(Hz)
0.0-999.9(A)
F(forward)/o(stop)/r(reverse)
0.00-99.99/100.0-999.9/1000. – 9999 . /
1000-9999/ 100- 999 (10000-99900)
(Example) FW, terminal 7,2, 1: ON
FW
8
7 6
5
4
3 2
1
(Example) Terminal 12,11:ON
AL 15 14 13
12
0.00-99.99/100.0-999.9/1000. – 9999 . /
1000-3996
-300.-+300.%
0.0-600.0 V
0.0-999.9 kW
0.-9999./1000-9999/ 100- 999 h
0.-9999./1000-9999/ 100- 999 h
0.-9999./1000-6553(10000-65530) (time)
Trip Code, frequency(Hz), current(A),
voltage(V),RUN time(h) power ON time(h)
Warning code
0.0, starting frequency-Max. frequency
n d
r d
(2
max. 3
max. frequency)(Hz)
0.01-99.99/100.0-999.9/1000. -3600.(s)
0.01-99.99/100.0-999.9/1000. -3600.(s)
0.01-99.99/100.0-999.9/1000. -3600.(s)
0.01-99.99/100.0-999.9/1000. -3600.(s)
0.01-99.99/100.0-999.9/1000. -3600.(s)
0.01-99.99/100.0-999.9/1000. -3600.(s)
00(forward)/01(reverse)
1–2
Terminal 8,6,5,4,3:OFF
ON
OFF
AL, 15,14,13:OFF
ON
OFF
(Note1)
Initial
Note
data
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.00
30.00
30.00
30.00
30.00
30.00
30.00
00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sj300 series

Table of Contents