Chapter 11
11.4 Safety function
The Safety function of P1-FS is equivalent to the function
listed below.
Function
Item
STO (Safe Torque Off)
STO
Stop category 0
SS1
SS1 (Safe stop 1)
Stop category 1
SBC
SBC(Safe brake control)
SLS
SLS(Safely-limited
SDI(Safe direction)
SDI
SSM
SSM(Safe speed
11.5 Response time
Item
Response time of STO output
Response time of SBC signal
11.6 Safety-related parameters
Parameter
Value
PL
e
CAT.
4
MTTFd
100 years
DCavg
99.6%
SIL
3
HFT
1
SFF
99.9%
PFH
4.08×10
-11
Standard
EN/IEC61800-5-2
EN 60204-1
EN/IEC61800-5-2
EN 60204-1
EN/IEC61800-5-2
speed)
EN/IEC61800-5-2
EN/IEC61800-5-2
monitor)
EN/IEC61800-5-2
Time
10ms max.
20ms max.
Standard
EN ISO/ISO 13849-1
IEC 61508
EN/IEC 61800-5-2
EN/IEC 62061
Specification and Technical data
11.7 Environmental specification
Ambient
temperature
Storage
temperature
Humidity
Vibration
Location
Required protection
rating of cabinet
*1) P1-00044-L(P1-004L) to P1-01240-L(P1-220L)/
P1-00041-H(P1-007H) to P1-00620-H(P1-220H)
*2) P1-01530-L(P1-300L) to P1-02950-L(P1-550L)/
P1-00770-H(P1-300H) to P1-03160-H(P1-1320H)
11.8 Supported version
Item
SJ-P1
ProDriveNext
Hitachi Inverter Tool
11-3
-10 to 50°C
-20 to 65°C
20 to 90%RH (No condensation)
2
*1)
5.9m/s
(0.6G),10 to 55Hz
*2)
2.94m/s
2
(0.3G),10 to 55Hz
Altitude 1,000m or less
Indoors (No corrosive gasses or dust)
IP54 or higher
Version
2.01 or later
2.3.22.0 or later
2.1.28.1 or later